Single Chlamydomonas reinhardi (C. reinhardtii) cell separation from bacterial cells and auto-fluorescence tracking with a nano-sieve device

G. Korensky, X. Chen, M. Bao, A. Miller, B. Lapizco-Encinas, M. Park, K. Du

Abstract

A planar, transparent, and adaptable nano-sieve device is developed for efficient microalgae/bacteria separation. In our strategy, a sacrificial layer is applied in the dual photolithography patterning to achieve a one-dimensional channel with a very low aspect ratio (1:10,000). Microalgae/bacteria mixture is then introduced into the deformable polydimethylsiloxane (PDMS) nano-channel. The hydrodynamic deformation of the nano-channel is regulated to allow the bacteria cells to pass through while leaving the microalgae cells trapped in the device. At a flow rate of 4 l/min, ~100% of the microalgae cells are trapped in the device. Additionally, this device is capable of immobilizing single cells in a transparent channel for auto-fluorescence tracking. These microalgae cells demonstrate minimal photo-bleaching over 250 s laser exposure and can be used to monitor hazardous compounds in the sample with a continuous flow fashion. Our method will be valuable to purify microalgae samples containing contaminations and study single cell heterogeneity.