Effect of Wall Motion Sampling on CFD-Derived Left Atrial Flow Metrics
Yvonne StöckeriD, Manuel Guerrero-Hurtado, Eduardo DurániD, Alejandro GonzaloiD, Zorica RistićiD, Åshild TelleiD, Ahmad KassariD, Romanos HaykaliD, NAZEM W. AKOUMiD, Patrick M. BoyleiD, Óscar FloresiD, Christoph M. AugustiniD, Juan C. del ÁlamoiD, Manuel García‐VillalbaiD
Abstract
The temporal resolution of medical imaging sequences used to drive patient-specific computational fluid dynamics (CFD) simulations remains limited, typically providing 10-20 frames per cardiac cycle. Therefore, temporal interpolation to reconstruct left atrial (LA) wall motion and boundary conditions is required, but its impact on hemodynamic predictions has not been systematically characterized. To investigate this, we constructed high-temporal-resolution reference wall-motion data using electromechanical (EM) simulations on five patient-specific atrial geometries with a history of atrial fibrillation. We then generated temporally downsampled datasets to emulate clinical frame rates (5, 10, 20, and 40 frames per cycle) and performed CFD simulations to isolate the effects of temporal undersampling on hemodynamic metrics. The focus was placed on kinetic energy, KE, and residence time, TR, particularly in the left atrial appendage (LAA), where thrombosis is most likely to occur. We employed an immersed boundary method to prescribe the wall motion and computed blood TR through a passive scalar transport equation. Results indicate that while global LA hemodynamic indices were marginally affected by the frame rate (errors < 9%), LAA metrics were more sensitive with errors up to 31% compared to reference values. The results based on 20 and 40 frames per cycle yielded favorable agreement with reference results, while 5-and 10-frame reconstructions showed larger, though not systematically biased, deviations from the reference. Importantly, patient ranking by blood-stasis indices was largely preserved. The analysis suggests that patientspecific LA reconstructions derived from dynamic CT imaging provide a reliable basis for estimating LAA blood-stasis indices. Higher frame rates ([≥] 20 per cycle) offer improved quantitative accuracy, while lower temporal resolutions may remain informative for patient stratification purposes, where relative ranking is more relevant than absolute accuracy.
- Citations
- 2
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Demonstration of Patient-Specific Simulations To Assess Left Atrial Appendage Thrombogenesis Risk
M. Garcia-Villalba, L. Rossini, … J. C. del Alamo·bioRxiv·May 7, 2020
- Left atrial flow and thrombosis risk from 4D CT contrast dynamics by physics-informed neural network and indicator dilution theory
Bahetihazi Maidu, Alejandro Gonzalo, … Juan C. del Álamo·bioRxiv·Apr 3, 2026
- Computational modeling of left ventricular flow using PC-CMR-derived four-dimensional wall motion
Seyed Babak Peighambari, Tanmay Mukherjee, … Reza Avazmohammadi·International Journal of Engineering SciencePeer-reviewed·Mar 23, 2026
- Fibrosis burden and spatial pattern affect left atrial appendage stasis in multi-beat multi-physics simulations
Yvonne Stöcker, Christoph M. Augustin, … Manuel García‐Villalba·bioRxiv·Oct 10, 2026
- Sensitivity of Pulmonary 4D Flow MRI Biomarkers to Controlled Spatial and Temporal Degradation in a CFD Benchmark
Aitor Zubillaga-Unsain, César Caballero‐Gaudes, Jesús Ruı́z-Cabello·bioRxiv·Oct 2, 2026
- Pulmonary vein flow split effects in patient-specific simulations of left atrial flow
E. Duran, M. Garcia-Villalba, … J. C. del Alamo·bioRxiv·Mar 24, 2023