bioRxivBiochemistryPreprint
Quantification of glutathione with high throughput live-cell imaging
X. Qi, J. Chen, X. Jiang, D. Lu, X. Yu, H. Lin, E. Y. Monroy, M. C. Wang, J. Wang
Abstract
Reduction oxidation (redox) reactions are central in life and altered redox state is associated with a spectrum of human diseases. Glutathione (GSH) is the most abundant antioxidant in eukaryotic cells and plays critical roles in maintaining redox homeostasis. Thus, measuring intracellular GSH level is an important method to assess the redox state of organism. The currently available GSH probes are based on irreversible chemical reactions with glutathione and cant monitor the real-time glutathione dynamics. Our group developed the first reversible reaction based fluorescent probe for glutathione, which can measure glutathione levels at high resolution using a confocal microscope and in the bulk scale with a flow cytometry. Most importantly it can quantitatively monitor the real-time GSH dynamics in living cells. Using the 2nd generation of GSH probe, RealThiol (RT), this study measured the GSH level in living Hela cells after treatment with varying concentrations of DL-Buthionine sulfoximine (BSO) which inhibits GSH synthesis, using a high throughput imaging system, Cytation 5 cell imaging reader. The results revealed that GSH probe RT at the concentration of 2.0 {micro}M accurately monitored the BSO treatment effect on GSH level in the Hela cells. The present results demonstrated that the GSH probe RT is sensitive and precise in GSH measurement in living cells at a high throughput imaging platform and has the potential to be applied to any cell lines.
- organism: human
- assay: imaging
- research focus: cell type annotation
- research focus: differential expression
- research focus: drug response / drug discovery
- approach: experimental assay
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- A Locally Activatable Sensor for Robust Quantification of Organellar Glutathione
S. Hübner, G. Quargnali, … P. Rivera-Fuentes·bioRxiv·Apr 1, 2022
- Quantitative Real-Time Imaging of Glutathione with Sub-Cellular Resolution
- Characterization of the Glutathione Redox State in the Golgi Apparatus
Carla Miró‐Vinyals, Sarah Hübner, … Pablo Rivera‐Fuentes·Redox BiologyPeer-reviewed·Feb 19, 2025
- Live monitoring of ROS-induced cytosolic redox changes with roGFP2-based sensors in plants
J. M. Ugalde, L. Fecker, … A. J. Meyer·bioRxiv·Dec 21, 2020
- Reduced glutathione decreases cell adhesion and increases cell volume.
- Measurement of the Glutathione Redox Potentials in Membraneless Organelles
Anna Rovira, Pablo Rivera‐Fuentes·bioRxiv·Mar 30, 2025