Sign in
BioengineeringbioRxiv

Simultaneous widefield voltage and interferometric dye-free optical mapping quantifies electromechanical waves in human iPSC-cardiomyocytes.

W. Liu, J. L. Han, J. Tomek, G. Bub, E. Entcheva

Abstract

Coupled electro-mechanical waves define hearts function in health and disease. Genetic abnormalities, drug-triggered or acquired pathologies can disrupt and uncouple these waves with potentially lethal consequences. Optical mapping of electrical waves using fluorescent dyes or genetically-encoded sensors in human induced pluripotent stem cell derived cardiomyocytes (iPSC-CMs) offers mechanistic insights into cardiac conduction abnormalities. Interferometric dye-free/label-free wave mapping (without specific sensors) presents an alternative, likely capturing the mechanical aspects of cardiac conduction. Because of its non-invasive nature and spectral flexibility (not restricted to a specific excitation wavelength), it is an attractive chronic imaging tool in iPSC-CMs, as part of all-optical high-throughput platforms. In this study, we developed simultaneous widefield voltage and interferometric dye-free optical imaging methodology that was used: 1) to validate dye-free optical mapping for quantification of cardiac wave properties in human iPSC-CMs; 2) to demonstrate low-cost optical mapping of electromechanical waves in hiPSC-CMs using recent near-infrared (NIR) voltage sensors and orders of magnitude cheaper miniature CMOS cameras; 3) to uncover previously underexplored frequency- and space-varying parameters of cardiac electromechanical waves in hiPSC-CMs. We find similarity in the frequency-dependent responses of electrical (NIR fluorescence imaged) and mechanical (dye-free imaged) waves, with the latter being more sensitive to faster rates and showing steeper restitution and earlier appearance of wave-front tortuosity. During regular pacing, the dye-free imaged conduction velocity and the electrical wave velocity are correlated; both modalities being sensitive to pharmacological uncoupling and both dependent on gap-junctional protein (connexins) determinants of wave propagation. We uncover strong frequency-dependence of the electromechanical delay (EMD) locally and globally in hiPSC-CMs on a rigid substrate. The presented framework and results offer new means to track the functional responses of hiPSC-CM inexpensively and non-invasively for counteracting heart disease and aiding cardiotoxicity testing and drug development.

PDFDOI

02 /Specification & Classification

Click any tag to browse matching papers

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.