bioRxivBioengineeringPreprint
High-performance Saccharomyces cerevisiae-based biosensor for heavy metal detection
Abstract
Heavy metals, i.e., Cu(II), are harmful to the environment. There is an increasing demand to develop inexpensive detection methods for heavy metals. Here, we developed a yeast biosensor with reduced-noise and improved signal output for potential on-site copper ion detection. The copper-sensing circuit was achieved by employing a secondary genetic layer to control the galactose-inducible (GAL) system in Saccharomyces cerevisiae. The reciprocal control of the Gal4 activator and Gal80 repressor under copper-responsive promoters resulted in a low-noise and ultrasensitive yeast biosensor for the copper ion detection. Furthermore, we developed a betaxanthin-based colorimetric assay, as well as 2-phenylethanol and styrene-based olfactory outputs for the copper ion detection. Notably, our engineered yeast sensor confers a narrow range switch-like behavior, which can give a "yes/no" response when coupled with betaxanthin-based visual phenotype. Taken together, we envision that the design principle established here might be applicable for developing other sensing systems for various chemical detections. IMPORTANCEThe accumulation of heavy metals in the environment led to an imbalance with environmental and ecological impacts, and there is an increasing demand for inexpensive methods that permit on-site detection of heavy metals. In this study, a yeast biosensor with reduced-noise and improved signal output was developed. We used a betaxanthin-based colorimetric assay for monitoring the copper contamination in water samples, which confers a switch-like behavior with a "yes/no" response. In addition, we also explored the 2-phenylethanol and styrene-based outputs for copper detection, which might be useful for olfactory detection of heavy metals.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Re-engineering of CUP1 promoter and Cup2/Ace1 transactivator to convert Saccharomyces cerevisiae into a whole-cell eukaryotic biosensor capable of detecting 10 nM of bioavailable copper
Bojan Žunar, Christine Mosrin-Huaman, … Béatrice Vallée·bioRxiv·Apr 4, 2022
- Development of the yeast Saccharomyces cerevisiae as a biosensor for the toxicity detection of toxic substances
- Development of a GFP Fluorescent Bacterial Biosensor for the Detection and Quantification of Silver and Copper Ions
Adam Radek Martinez, John R. Heil, Trevor C. Charles·bioRxiv·Apr 6, 2018
- "Scentsor": A Whole-Cell Yeast Biosensor with an Olfactory Reporter for Low-Cost and Equipment-Free Detection of Pharmaceuticals
Rachel A. Miller, Seryeong Lee, … Holly V. Goodson·ACS SensorsPeer-reviewed·Sep 23, 2020
- A simple chromogenic whole-cell arsenic biosensor based on Bacillus subtilis
Niels Wicke, David S. Radford, Christopher E. French·bioRxiv·Aug 19, 2018
- Humanized CB1R and CB2R yeast biosensors enable facile screening of cannabinoid compounds
Colleen J. Mulvihill, Josh Lutgens, … Elizabeth C. Gardner·bioRxiv·Oct 12, 2022