Material Composition and Implantation Site Affect in vivo Device Degradation Rate
Kendell M. PaweleciD, Jeremy M.L. HixiD, Arianna TroiaiD, Niharika SinhaiD, Keith W. MacRenarisiD, Matti KiupeliD, Thomas V. O’HalloraniD, Erik M. ShapiroiD
Abstract
Successful tissue engineering requires biomedical devices that initially stabilize wounds, then degrade as tissue is regenerated. However, the material degradation rates reported in literature are often conflicting. Incorporation of in situ monitoring functionality into implanted devices would allow real time assessment of degradation and potential failure. This necessitates introduction of contrast agent as most biomedical devices are composed of polymeric materials with no inherent contrast in medical imaging modalities. In the present study, computed tomography (CT)-visible radiopaque composites were created by adding 5-20wt% tantalum oxide (TaOx) nanoparticles into polymers with distinct degradation profiles: polycaprolactone (PCL), poly(lactide-co-glycolide) (PLGA) 85:15 and PLGA 50:50, representing slow, medium and fast degrading materials respectively. Radiopaque phantoms, mimicking porous tissue engineering devices, were implanted into mice intramuscularly or intraperitoneally, and monitored via CT over 20 weeks. Changes in phantom volume, including collapse and swelling, were visualized over time. Phantom degradation profile was determined by polymer matrix, regardless of nanoparticle addition and foreign body response was dictated by the implant site. In addition, degradation kinetics were significantly affected in mid-degrading materials, transitioning from linear degradation intramuscularly to exponential degradation intraperitoneally, due to differences in inflammatory responses and fluid flow. Nanoparticle excretion from degraded phantoms lagged behind polymer, and future studies will modulate nanoparticle clearance. Utilizing in situ monitoring, this study seeks to unify literature and facilitate better tissue engineering devices, by highlighting the relative effect of composition and implant site on important materials properties.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 8
- FWCI
- 5.23
- Field percentile
- top 4%
- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- In vivo Biomedical Imaging of Immune Tolerant, Radiopaque Nanoparticle-Embedded Polymeric Device Degradation
K. Pawelec, J. M. L. Hix, … E. Shapiro·bioRxiv·Oct 26, 2023
- Incorporating Radiopacity into Implantable Polymeric Biomedical Devices for Clinical Radiological Monitoring
K. M. Pawelec, E. Tu, … E. Shapiro·Advanced Healthcare MaterialsPeer-reviewed·Mar 13, 2023
- Distinct Roles of Surface Nanostructure and Polymer Degradation in Fibroblast Response to Device Design
Kendell M. Pawelec, Erik M. Shapiro·Biomedical Materials & DevicesPeer-reviewed·Mar 24, 2026
- Characterizing in vivo degradation of electrospun biodegradable nanofibers by size-exclusion chromatography
Shingo Kunioka, Takumi Yoshida, … Kyohei Oyama·bioRxiv·May 13, 2026
- Radiopaque Implantable Biomaterials for Nerve Repair
K. M. Pawelec, J. M. L. Hix, E. M. Shapiro·bioRxiv·Jan 5, 2023
- Computed Tomography of Polymeric Biomedical Implants from Bench to Bedside
Kendell M. Pawelec, Todd Andrew Schoborg, Erik M. Shapiro·Journal of Biomedical Materials Research Part APeer-reviewed·May 10, 2024