bioRxivNeurosciencePreprint
High-frequency sampling rate reduces TMS-pulse artifact duration but not decay artifact: implications for immediate TMS-EEG responses
Antonietta StangoiD, Agnese ZazioiD, Guido BarchiesiiD, Natale Salvatore BonfiglioiD, Marta BortolettoiD
Abstract
In studies combining transcranial magnetic stimulation and electroencephalography (TMS-EEG), two artifacts appear instantly after the TMS pulse, i.e., the TMS-pulse Artifact and the Decay Artifact, and limit the possibility to measure immediate cortical excitability responses. High-frequency sampling rates in EEG recordings have shown promise in reducing artifact duration, allowing more rapid signal recovery, which is crucial for developing biomarkers for neuropsychiatric conditions. However, the features of early TMS-induced artifacts for sampling rates above 5000 Hz are still unclear. Here, we explored the duration of TMS artifacts in the first milliseconds after TMS to understand how they can be further reduced in future studies. We recorded from a phantom head model and from a simple electrical circuit with a sampling rate of 4800 Hz, 9600 Hz, and 19200 Hz and at three TMS intensities (40%, 70%, 100% of maximum stimulator output) in two commercial stimulators. Results showed an initial sharp TMS-pulse Artifact lasting less than 1 ms and decreasing in duration at higher sampling rates. However, the signal was back to baseline at about 2-3 ms due to the presence of a decay artifact that was evident even in optimal conditions of low impedance and mostly dependent on stimulation intensity. These results highlight the need to develop efficient ways to eliminate the decay artifact in order to measure immediate TMS responses.
- Citations
- 1
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- The effect of EEG lead configuration on early TMS-EEG artifacts
Kaisu Lankinen, Gabriel Fadel, … Tommi Raij·bioRxiv·Feb 12, 2026
- Characterising and Minimising Step and Filtering Artifacts in TMS-EEG Recordings
Marissa M. Holden, Mitchell R. Goldsworthy, … Nigel C. Rogasch·bioRxiv·May 18, 2026
- The rt-TEP tool: real-time visualization of TMS-Evoked Potential to maximize cortical activation and minimize artifacts
Silvia Casarotto, Matteo Fecchio, … Marcello Massimini·Journal of Neuroscience MethodsPeer-reviewed·Jan 21, 2022
- The impact of artifact removal approaches on TMS-EEG signal
Giacomo Bertazzoli, Romina Esposito, … Marta Bortoletto·NeuroImagePeer-reviewed·Jun 16, 2021
- Signal-space projection suppresses the tACS artifact in EEG recordings
Johannes Vosskuhl, Tuomas P. Mutanen, … Christoph Siegfried Herrmann·Frontiers in Human NeurosciencePeer-reviewed·Dec 18, 2020
- Experimental Evaluation of Methods for Real-Time EEG Phase-Specific Transcranial Magnetic Stimulation