Abstract
BackgroundMultivariate pattern analysis (MVPA) has proven an excellent tool in cognitive neuroscience used M/EEG, and MRI. It also holds a strong promise when applied to optically-pumped magnetometer-based magnetoencephalography. New methodTo optimize OPM-MEG systems for MVPA experiments this study examines data from a conventional MEG magnetometer array, focusing on appropriate noise reduction techniques for magnetometers. We also determined the least required number of sensors needed for robust MVPA for image categorization experiments. ResultsWe found that the use of signal space separation (SSS) significantly lowered the classification accuracy considering a sub-array of 102 magnetometers or a sub-array of 204 gradiometers. We also found that classification accuracy did not improve when going beyond 30 sensors irrespective of whether SSS has been applied. Comparison with existing methodsThe power spectra of data filtered with SSS has a substantially higher noise floor that data cleaned with SSP or HFC. Consequently, the MVPA decoding results obtained from the SSS-filtered data are significantly lower compared to all other methods employed. ConclusionsWhen designing an MEG system based on SQUID magnetometers optimized for multivariate analysis for image categorization experiments, about 30 magnetometers are sufficient. We advise against applying SSS filters to data from MEG and OPM systems prior to performing MVPA as this method, albeit reducing low-frequency external noise contributions, also introduces an increase in broadband noise. We recommend employing noise reduction techniques that either decrease or maintain the noise floor of the data like signal-space projection, homogeneous field correction and gradient noise reduction. HighlightsO_LIA sensor array of about 30 sensors is sufficient for multivariate pattern analysis using conventional MEG magnetometers for image classification. C_LIO_LIUsing signal space separation filter on magnetometer data prior to multivariate pattern analysis might reduce classification accuracy due to an increase in white noise in the data contributed by the algorithm. C_LIO_LIWhen performing multivariate data analysis, other noise reduction approaches that diminish the contribution of external noise sources and reduce the variance of the data are advisable such as synthetic gradiometers, signal space projection or homogeneous field correction. C_LI
- assay: electronic health records
- research focus: benchmarking
- approach: statistical model
- approach: experimental assay
- Citations
- 10
- FWCI
- 1.59
- Field percentile
- top 16%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Decoding with multivariate pattern analysis is superior for optically pumped magnetometer-based magnetoencephalography compared to superconducting quantum interference device-based systems
Junlin Liang, Yulia Bezsudnova, … Ole B. Jensen·bioRxiv·Oct 14, 2025
- Pragmatic spatial sampling for wearable MEG arrays
Tim M. Tierney, Stephanie Mellor, … Gareth Robert Barnes·Scientific ReportsPeer-reviewed·Dec 10, 2020
- Adaptive multipole models of OPM data.
Tim M. Tierney, Zelekha A. Seedat, … Gareth Robert Barnes·bioRxiv·Sep 11, 2023
- Noise Optimization of Basic Signal Component Extraction for Cryogenic and On-Scalp Magnetoencephalography (MEG)
Allen L. McPherson, Sepp Sanchirico, … Samu Taulu·bioRxiv·Jul 26, 2026
- Measuring MEG closer to the brain: Performance of on-scalp sensor arrays
Joonas Iivanainen, Matti Stenroos, Lauri T. Parkkonen·NeuroImagePeer-reviewed·Dec 19, 2016
- Noise Reduction and Localization Accuracy in a Mobile Magnetoencephalography System
Timothy Bardouille, Vanessa Smith, … Niall Holmes·SensorsPeer-reviewed·May 29, 2024