Frontiers in NeuroscienceNeurosciencePeer-reviewed journal article
Does impedance matter when recording spikes with polytrodes?
Joana P. NetoiD, Pedro Baião, Gonçalo LopesiD, João FrazãoiD, Joana Nogueira, Elvira M. C. FortunatoiD, Pedro Miguel Cândido BarquinhaiD, Adam R. KampffiD
Abstract
Extracellular microelectrodes have been widely used to measure brain activity, yet there are still basic questions about the requirements for a good extracellular microelectrode. One common source of confusion is how an electrodes impedance affects the amplitude of extracellular spikes and background noise.\n\nHere we discuss how an electrodes impedance affects data quality in extracellular recordings, which is crucial for both the detection of spikes and their assignment to the correct neurons. This study employs commercial polytrodes containing 32 electrodes (177 m2) arranged in a dense array. This allowed us to directly compare, side-by-side, the same extracellular signals measured by modified low impedance (~100 kOhm) microelectrodes with unmodified high impedance (~1 MOhm) microelectrodes. We begin with an evaluation of existing protocols to lower the impedance of the electrodes. The poly(3,4-ethylenedioxythiophene)-polystyrene sulfonate (PEDOT-PSS) electrodeposition protocol is a simple, stable, and reliable method for decreasing the impedance of a microelectrode up to tenfold. We next record in vivo using polytrodes that are modified in a chess board pattern, such that the signal of one neuron is detected by multiple coated and non-coated electrodes. The performance of the coated and non-coated electrodes is then compared on measures of background noise and amplitude of the detected action potentials.\n\nIf the proper recording system is used, then the impedance of a microelectrode within the range of standard polytrodes (~ 0.1 to 2 MOhm) does not significantly affect data quality and spike sorting. This study should encourage neuroscientists to stop worrying about one more unknown.
- Citations
- 106
- FWCI
- 4.45
- Field percentile
- top 4%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Sputtered porous Pt for wafer-scale manufacture of low-impedance flexible microelectrodes
B. Fan, A. V. Rodriguez, … J. T. Robinson·bioRxiv·Feb 4, 2020
- Impedance scaling for gold and platinum microelectrodes
B. Fan, B. Wolfrum, J. Robinson·Journal of Neural EngineeringPeer-reviewed·Sep 9, 2021
- Extracellular and intracellular components of the impedance of neural tissue
Claude Bedard, Charlotte Piette, … Alain Destexhe A·Biophysical JournalPeer-reviewed·Feb 16, 2022
- Rejuvenating silicon probes for acute electrophysiology
Alden M. Shoup, Natasha Porwal, … Reza Shadmehr·bioRxiv·Feb 20, 2024
- Nanoporous Platinum Microelectrode Arrays for Neuroscience Applications
Nicolai Winter‐Hjelm, Leik Isdal, … Pawel Sikorski·RSC AdvancesPeer-reviewed·Jan 1, 2025
- High-performance Flexible Microelectrode Array with PEDOT:PSS Coated 3D Micro-cones for Electromyographic Recording
J. Lu, M. Zia, … M. S. Bakir·bioRxiv·Feb 3, 2022