Fieldable isothermal nucleic acid test for rapid semi-quantitative visual readout of Enterococci in recreational waters
Anirudh Sudarshan, Meredith G. Rillera, Nicholas D. TraniD, Timothy E. RiedeliD, Andrew D. EllingtoniD, Sanchita BhadraiD
Abstract
Enterococci are fecal indicator bacteria whose presence in water suggests the potential for gastrointestinal pathogens. Culture-based detection is slow and may require expensive apparatus and proprietary media. Molecular tests based on qPCR can be technically difficult and require complex devices. Loop-mediated isothermal amplification (LAMP) tests that need minimal instrumentation have been described but they only qualitatively indicate presence or absence of Enterococci, which is difficult to compare with quantitative contamination standards for assessing water quality. Here, we demonstrate semi-quantitative thresholded LAMP that uses internal competition with pre-defined false targets and an oligonucleotide strand displacement (OSD) probe to measure the degree of Enterococcus contamination in water. The assay needs only one hour of incubation at a single temperature following which a simple visual examination of endpoint OSD fluorescence allows order of magnitude scale estimation of Enterococcus amounts. Environmental water samples with low, medium, and high Enterococcus contamination could be readily distinguished by thresholded LAMP-OSD without interference from non-specific signals. LAMP-OSD performance correlated with the outcomes of both qPCR and plate cultures of the samples. The simplicity of implementing thresholded LAMP-OSD makes it well suited for point-of-need and low-cost water quality monitoring.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- FWCI
- 0.00
- Field percentile
- 26th percentile
- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- QT-AMP: Quanti-Tray-based amplicon sequencing for simultaneous quantification and identification of enterococci for microbial source tracking
H. Urakawa, T. L. Hancock, … R. A. Armstrong·bioRxiv·Aug 2, 2021
- Validity Assessment of Michigan's Proposed qPCR Threshold Value for Rapid Water-Quality Monitoring of E. coli Contamination
J. N. McNair, M. J. Lane, … R. R. Rediske·bioRxiv·Jul 16, 2022
- Development and evaluation of a rapid on-site water pathogen detection system for water quality monitoring
J. Y. Chia, Y. P. Tay, … C.-L. K. Lee·bioRxiv·Aug 10, 2019
- High-throughput multi-parallel enteropathogen quantification via nano-liter qPCR
J. A. Grembi, K. Mayer-Blackwell, … A. M. Spormann·Frontiers in Cellular and Infection MicrobiologyPeer-reviewed·Jul 15, 2020
- Development of Loop Mediated Isothermal Amplification for Rapid and Sensitive Detection of Enteroaggregative Escherichia coli (EAEC).
Alazar Amare Amdiyee, Tesfaye Sisay Tessema·bioRxiv·Nov 4, 2025
- Multiplex LAMP for Simplified Monitoring Cryptosporidium and Giardia in Surface Water
J. E. Ongerth, F. M. A. Saaed·bioRxiv·Aug 18, 2020