Multi-Layer Brain-Mimicking Phantom for Replicating Dura and Pia Membrane Dimpling and Rupture Properties During Neural Interface Implantation
Abstract
Development of novel neural interfaces faces buckling challenges and heavily relies on trial-and-error tests via in vivo animal brain insertions for design optimizations towards the minimal-damaging version for enhanced recording and stimulation outcome. To enable low-cost and fast-turnaround neural interface development and to enable previously impossible insertions via new understanding of the cutting process, this study developed a reproducible, multi-layer brain-mimicking phantom designed to replicate the rodent pia and dura mater dimpling and rupture force performance observed during in vivo tests. The phantom was composed of a 0.5% (w/v) agarose cortex layer, a 1.01% (w/v) agarose pia mater layer, and a pre-stretched polyvinyl chloride (PVC) dura mater layer, assembled via easily duplicable benchtop protocols. Using a cantilever-beam force measurement system, rupture force and dimpling depth were quantified across microwires of varying diameters (12-100 m), materials (tungsten, stainless steel), and tip geometries, as well as segmented silicon probe shanks. Phantom test results closely matched in vivo Sprague-Dawley rat data, validating the performance of the developed multi-layer phantom. At the same time, phantom insertion trial variability was substantially lower than in vivo tests, enabling a repeatable, low-cost, early-stage screening platform of novel electrode designs. The phantoms modular design also allowed tuning of layer thickness and stifness of each layer for diferent species or devices, ofering a validated customizable testing platform to accelerate novel neural implant development and reduce animal use.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 1
- FWCI
- 2.49
- Field percentile
- top 9%
- Organism
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- A multimodal brain phantom for noninvasive neuromodulation
John LaRocco·bioRxiv·Oct 13, 2025
- Ultra-sensitive measurement of brain penetration mechanics and blood vessel rupture with microscale probes
Abdulmalik Obaid, Mina-Elraheb S. Hanna, … Yu‐Wei Wu·Proceedings of the National Academy of SciencesPeer-reviewed·Mar 26, 2026
- The \"sewing machine\" for minimally invasive neural recording
Timothy Hanson, Camilo A. Diaz-Botia, … Philip N. Sabes·bioRxiv·Mar 14, 2019
- Curved flexible neural interfaces for laminar electrophysiology in deep-brain structures
Jo’Elen Hagler, Lucia Pizzoccaro, … Fabio Cicoira·bioRxiv·Sep 29, 2025
- Stiffness-tunable neurotentacles for minimally invasive implantation and long-term neural activity recordings
Yang Wang, Xing Xu, … Weihua Pei·Advanced SciencePeer-reviewed·Jul 21, 2025
- Intracortical probe arrays with silicon backbone and microelectrodes on thin polyimide wings enable long-term stable recordings in vivo
Antje Kilias, Yu‐Tao Lee, … Patrick Ruther·Journal of Neural EngineeringPeer-reviewed·Nov 15, 2021