Proceedings of the National Academy of SciencesNeurosciencePeer-reviewed journal article
Ultra-sensitive measurement of brain penetration mechanics and blood vessel rupture with microscale probes
Abdulmalik ObaidiD, Mina-Elraheb S. HannaiD, Song-Wen HuangiD, Yu-Ting HuiD, Omar JáidariD, William D. Nix, Jun DingiD, Nicholas A. MeloshiD, Yu‐Wei WuiD
Abstract
Microscale electrodes, on the order of 10-100 m, are rapidly becoming critical tools for neuroscience and brain-machine interfaces (BMIs) for their high channel counts and spatial resolution, yet the mechanical details of how probes at this scale insert into brain tissue are largely unknown. Here, we performed quantitative measurements of the force and compression mechanics together with real-time microscopy for in vivo insertion of a systematic series of microelectrode probes as a function of diameter (7.5-100 m and rectangular Neuropixels) and tip geometry (flat, angled, and electrochemically sharpened). Results elucidated the role of tip geometry, surface forces, and mechanical scaling with diameter. Surprisingly, the insertion force post-pia penetration was constant with distance and did not depend on tip shape. Real-time microscopy revealed that at small enough lengthscales (<25 m), blood vessel rupture and bleeding during implantation could be entirely avoided. This appears to occur via vessel displacement, avoiding capture on the probe surface which led to elongation and tearing for larger probes. We propose a new, three-zone model to account for the probe size dependence of bleeding, and provide mechanistic guidance for probe design. Significance StatementMicroscale neural probes are central to next-generation brain-machine interfaces, yet how they physically penetrate living brain remains poorly quantified. Using a high-sensitivity force sensor integrated with real-time microscopy, we measured in vivo force-displacement and visualized vascular responses for microwires (7.5-100 m) and Neuropixels. We find that once the brains protective pia membrane is breached, insertion force remains essentially constant with depth, while pia puncture force and pre-penetration compression scale linearly with probe diameter. Real-time imaging reveals a sub-25 m regime in which blood vessels are displaced rather than ruptured. These results motivate a three-zone model of vessel capture versus displacement and provide actionable mechanical design rules for low-trauma, high-density neural interfaces.
- Citations
- 28
- FWCI
- 9.86
- Field percentile
- top 2%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Ultra-sensitive measurement of brain penetration with microscale probes for brain machine interface considerations
Abdulmalik Obaid, Yu‐Wei Wu, … Nicholas A. Melosh·bioRxiv·Oct 29, 2018
- Ultra-flexible endovascular probes for brain recording through micron-scale vasculature
A. Zhang, E. T. Mandeville, … C. M. Lieber·bioRxiv·Mar 20, 2023
- The \"sewing machine\" for minimally invasive neural recording
Timothy Hanson, Camilo A. Diaz-Botia, … Philip N. Sabes·bioRxiv·Mar 14, 2019
- Double-layer flexible neuronal probe with closely spaced electrodes for high-density in vivo brain recordings
S. Pimenta, J. A. Rodrigues, … L. Jacinto·bioRxiv·Oct 15, 2020
- Stiffness-tunable neurotentacles for minimally invasive implantation and long-term neural activity recordings
Yang Wang, Xing Xu, … Weihua Pei·Advanced SciencePeer-reviewed·Jul 21, 2025
- Mechanical characterization of compliant neural probes, their insertion regimes and a rule of thumb design
Zac Smith·bioRxiv·Sep 18, 2019