bioRxivBiochemistryPreprint
Advancing the Application of pXRF for Biological Samples
Abstract
Point 1: Portable x-ray fluorescent (pXRF) technology provides significant opportunities for rapid, non-destructive data collection in a range of fields of study. However, there are sources of variation and sample assumptions that may influence the data obtained, particularly in biological samples. Point 2: We used representative species for four taxa (fish, mammals, birds, reptiles) to test the precision of replicate scans, and the impact of sample thickness, sample state, scan location and scan time on data obtained from a pXRF. Point 3: We detected significant differences in concentration data due to sample state, scanning time and scanning location for all taxa. Infinite thickness assumptions were met for fish, reptile and mammal representatives at all body locations when samples were thawed, but not dried. Infinite thickness was not met for feathers. Scan time results found in most cases the 40, 60 and 80 second beam times were equivalent. Concentration data across replicate scans were highly correlated. Point 4: The opportunities for the use of pXRF in biological studies are wide-ranging. These findings highlight the considerations required when scanning biological samples to ensure the required data are suitably collected, while maintaining minimal radiation exposure to live animals.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Portable X-ray Fluorescence for Measuring Lead in the Hair of Wild Mammals
E. M. Jones, A. J. Bengsen, … J. O. Hampton·bioRxiv·Mar 13, 2023
- X-ray fluorescence microscopy exposure estimates using a single excitation energy
Benjamin Roter, Andrew M. Crawford, … Chris J. Jacobsen·Journal of Synchrotron RadiationPeer-reviewed·Jun 2, 2026
- Micro-XRF study of the troodontid dinosaur Jianianhualong tengi reveals new biological and taphonomical signals
- Physiological responses of plants to in vivo XRF radiation damage: insights from elemental, histochemical, anatomical and ultrastructural analyses
G. S. Montanha, J. P. R. Marques, … H. W. P. de Carvalho·bioRxiv·Jan 18, 2022
- Blank Spectrum Correction as a Robust Solution to Artifacts in Quantitative X-ray Fluorescence Mapping
Andrew M. Crawford, Julia Balough, … Thomas V. O’Halloran·Analytical ChemistryPeer-reviewed·Sep 16, 2026
- A novel sample delivery method for powder X-ray diffraction at Turkish Light Source
Esra Beyarslan Ayan, Abdullah Kepçeoğlu, Arif Mermer·bioRxiv·Apr 27, 2026