Analytical ChemistryBiophysicsPeer-reviewed journal article
Blank Spectrum Correction as a Robust Solution to Artifacts in Quantitative X-ray Fluorescence Mapping
Andrew M. CrawfordiD, Julia Balough, Yu-Ying CheniD, Qiaoling JiniD, Keith W. MacRenarisiD, Seth A. GarwiniD, Teresa K. WoodruffiD, Chris J. JacobseniD, James E. Penner‐HahniD, Thomas V. O’HalloraniD
Abstract
X-ray fluorescence microscopy (XFM) continues to develop as a powerful quantitative technique for high resolution, label-free, elemental mapping of biological, environmental, and material samples. Methods for rigorously fitting spectra, increasing throughput, accounting for background signals, and deconvoluting overlapping emission lines continue to evolve. We show here that quantitative fits of XFM data obtained after removing a baseline, calculated by connecting peak edges, can be unexpectedly dependent upon acquisition dwell-time and spectral aggregation leading to differences in apparent elemental content. Using mouse preimplantation embryos and ovarian follicles as model samples, we demonstrate how these variables influence quantitative comparisons between samples. We find that subtracting an empirically measured blank spectrum instead of a baseline provides quantitative XFM elemental mapping results that are independent of dwell time and spectral aggregation dependencies.
- Citations
- 0
- FWCI
- 0.00
- Field percentile
- top 40%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- X-ray fluorescence microscopy exposure estimates using a single excitation energy
Benjamin Roter, Andrew M. Crawford, … Chris J. Jacobsen·Journal of Synchrotron RadiationPeer-reviewed·Jun 2, 2026
- Multifunctional bending magnet beamline with a capillary optic for X-ray fluorescence studies of metals in tissue sections
Benjamin Roter, Andrew M. Crawford, … Chris J. Jacobsen·Journal of Synchrotron RadiationPeer-reviewed·Feb 13, 2026
- Building Fluorescence Lifetime Maps Photon-by-photon by Leveraging Spatial Correlations
- Physiological responses of plants to in vivo XRF radiation damage: insights from elemental, histochemical, anatomical and ultrastructural analyses
G. S. Montanha, J. P. R. Marques, … H. W. P. de Carvalho·bioRxiv·Jan 18, 2022
- Correlative transmission electron microscopy and high-resolution hard X-ray fluorescence microscopy of cell sections to measure trace elements concentrations at the organelle level
V. Tardillo Suarez, B. Gallet, … A. Deniaud·Journal of Structural BiologyPeer-reviewed·Sep 1, 2021
- Advancing the Application of pXRF for Biological Samples
K. Brandis, R. Francis·bioRxiv·Jan 16, 2024