Robust Normalization of Luciferase Reporter Data
Abstract
Transient Luciferase reporter assays are widely used in the study of gene regulation and intracellular cell signaling. In order to control for sample-to-sample variation in luminescence arising from variability in transfection efficiency and other sources, an internal control reporter is co-transfected with the experimental reporter. The luminescence of the experimental reporter is normalized against the control by taking the ratio of the two. Here we show that this method of normalization, \"ratiometric\", performs poorly when the transfection efficiency is low and leads to biased estimates of relative activity. We propose an alternative methodology based on linear regression that is much better suited for the normalization of reporter data, especially when transfection efficiency is low. We compare the ratiometric method against three regression methods on both simulated and empirical data. Our results suggest that robust errors-in-variables (REIV) regression performs the best in normalizing Luciferase reporter data. We have made the R code for Luciferase data normalization using REIV available on GitHub.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 11
- FWCI
- 0.75
- Field percentile
- top 33%
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- PlotXpress, a webtool for normalization and visualization of reporter expression data
Elias Brandorff, Marc Galland, Joachim Goedhart·F1000ResearchPeer-reviewed·Nov 8, 2021
- LucFlow: A method to measure Luciferase reporter expression in single cells
Sunil K Nooti, Madison Naylor, … Manu·PLoS ONEPeer-reviewed·Oct 4, 2023
- Variation-preserving normalization unveils blind spots in gene expression profiling
Carlos P. Roca, Susana I. L. Gomes, … Janeck J. Scott-Fordsmand·bioRxiv·Dec 4, 2015
- A ratiometric dual color luciferase reporter for fast characterization of transcriptional regulatory elements
Eduardo González Grandío, Gözde S. Demirer, … Markita Patricia Landry·ACS Synthetic BiologyPeer-reviewed·Sep 14, 2021
- Reconstructing Promoter Activity From Lux Bioluminescent Reporters
Mudassar Iqbal, Neil Doherty, … Dov Joseph Stekel·PLoS Computational BiologyPeer-reviewed·Sep 18, 2017
- Comparison of the 2-CT method and the 2-ΔΔCT method for real-time qPCR data analysis
Lixiang Feng, Rongqian Zhao, … Wenxing Yang·Peer-reviewed journalPeer-reviewed·Sep 20, 2025