Magnetic Resonance Spectroscopy Frequency and Phase Correction Using Convolutional Neural Networks
David J. MaiD, Hortense Le, Yuming Ye, Andrew F. LaineiD, Jeffery A. Lieberman, Douglas L. RothmaniD, Scott A. SmalliD, Jia GuoiD
Abstract
We introduce DeepSPEC, a novel convolutional neural network (CNN) -based approach for frequency-and-phase correction (FPC) of MRS spectra to achieve fast and accurate FPC of single-voxel PRESS MRS and MEGA-PRESS data. In DeepSPEC, two neural networks, including one for frequency correction and one for phase correction were trained and validated using published simulated and in vivo PRESS and MEGA-PRESS MRS dataset with wide-range artificial frequency and phase offsets applied. DeepSPEC was subsequently tested and compared to the current deep learning solution - a "vanilla" neural network approach using multilayer perceptrons (MLP). Furthermore, random noise was added to the original simulated dataset to further investigate the model performance with noise at varied signal-to-noise (SNR) levels (i.e., 6 dB, 3 dB, and 1.5 dB). The testing showed that DeepSPEC is more robust to noise compared to the MLP-based approach due to having a smaller absolute error in both frequency and phase offset prediction. The DeepSPEC framework was capable of correcting frequency offset with 0.01{+/-}0.01 Hz and phase offset with 0.12{+/-}0.09{degrees} absolute errors on average for unseen simulated data at a high SNR (12 dB) and correcting frequency offset with 0.01{+/-}0.02 Hz and phase offset within -0.07{+/-}0.44{degrees} absolute errors on average at very low SNR (1.5 dB). Furthermore, additional frequency and phase offsets (i.e., small, moderate, large) were applied to the in vivo dataset, and DeepSPEC demonstrated better performance for FPC when compared to the MLP-based approach. Results also show DeepSPEC has superior performance than the model-based SR implementation (mSR) in FPC by having higher accuracy in a wider range of additional offsets. These results represent a proof of concept for the use of CNNs for preprocessing MRS data and demonstrate that DeepSPEC accurately predicts frequency and phase offsets at varying noise levels with state-of-the-art performance.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 20
- FWCI
- 1.85
- Field percentile
- top 14%
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Magnetic Resonance Spectroscopy Spectral Registration Using Deep Learning
David J. Ma, Yanting Yang, … Jia Guo·Journal of Magnetic Resonance ImagingPeer-reviewed·Jul 4, 2023
- Model-Informed Unsupervised Deep Learning Approaches to Frequency and Phase Correction of MRS Signals
Amirmohammad Shamaei, Jana Starčuková, … Zenon Starčuk·Magnetic Resonance in MedicinePeer-reviewed·Nov 11, 2022
- Frequency and Phase Correction of GABA-Edited Magnetic Resonance Spectroscopy using Complex-Valued Convolutional Neural Networks
Hanna Bugler, Rodrigo Berto, … Ashley D. Harris·Magnetic Resonance ImagingPeer-reviewed·May 12, 2024
- Model-based frequency-and-phase correction of 1H MRS data with 2D linear-combination modeling.
Dunja Simičić, Helge J. Zöllner, … Georg Oeltzschner·bioRxiv·Mar 26, 2024
- DeepRetroMoCo: Deep neural network-based Retrospective Motion Correction Algorithm for Spinal Cord functional MRI
Mahdi Mobarak-Abadi, Ahmad Mahmoudi-Aznaveh, … Ali Khatibi·Frontiers in PsychiatryPeer-reviewed·Jun 28, 2024
- Evaluations of retrospective frequency and phase correction methods for single-voxel MR spectroscopy at 7T
Chu‐Yu Lee, Jia Xu, … Vincent A. Magnotta·bioRxiv·Sep 22, 2026