Multi-center benchmarking of cervical spinal cord RF coils for 7 T MRI: A traveling spines study
Eva Alonso‐OrtiziD, Daniel PappiD, Robert L BarryiD, Kyota Poëti, Alan C. SeifertiD, Kyle M. GilbertiD, Nibardo Lopez RiosiD, Jan Paška, Falk EippertiD, Nikolaus WeiskopfiD, Laura BeghiniiD, Nadine N. GraedeliD, Robert TrampeliD, Martina F. CallaghaniD, Christoph Stefan AigneriD, Patrick FreundiD, Maryam SeifiD, Aurélien DestrueliD, Virginie CallotiD, S. Johanna VannesjoiD, Julien Cohen‐AdadiD
Abstract
PurposeThe depth within the body, small diameter, long length, and varying tissue surrounding the spinal cord impose specific considerations when designing radiofrequency coils. The optimal coil configuration for 7 T cervical spinal cord MRI is unknown and, currently, there are very few coil options. The purpose of this work was (1) to establish a quality control protocol for evaluating 7 T cervical spinal cord coils and (2) to use that protocol to evaluate the performance of 4 different coil designs. MethodsThree healthy volunteers and a custom anthropomorphic phantom (the traveling spines cohort) were scanned at seven 7 T imaging centers using a common protocol and each centers specific cervical spinal cord coil. Four different coil designs were tested (two in-house, one Rapid Biomedical, and one MRI.TOOLS design). ResultsThe Rapid Biomedical coil was found to have the highest B1+ efficiency, whereas one of the in-house designs (NeuroPoly Lab) had the highest SNR and the largest spinal cord coverage. The MRI.TOOLS coil had the most uniform B1+ profile along the cervical spinal cord; however, it was limited in its ability to provide the requested flip angles (especially for larger individuals). The latter was also the case for the second in-house coil (MSSM). ConclusionThe results of this study serve as a guide for the spinal cord MRI community in selecting the most suitable coil based on specific requirements and offer a standardized protocol for assessing future coils.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 5
- FWCI
- 2.87
- Field percentile
- top 10%
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- 8-channel Tx dipole and 20-channel Rx loop coil array for MRI of the cervical spinal cord at 7 Tesla
N. L. Rios, K. M. Gilbert, … J. Cohen-Adad·bioRxiv·Feb 8, 2023
- Integration of a radiofrequency coil and commercial field camera for ultra-high-field MRI
K. M. Gilbert, P. Dubovan, … C. A. Baron·bioRxiv·Sep 27, 2021
- Thermal Stimulus Task fMRI in the Cervical Spinal Cord at 7 Tesla
A. C. Seifert, J. Xu, … S. J. Vannesjo·bioRxiv·Jan 31, 2023
- Practical TMS coils with maximum focality and various stimulation depths
Luis J. Gomez, Lari M. Koponen, … Angel V. Peterchev·bioRxiv·Aug 12, 2025
- Comparison of MR coil options for concurrent TMS-fMRI
Jade B. Jackson, Catriona L. Scrivener, … Alexandra Woolgar·bioRxiv·May 15, 2024
- Single Channel Strongly-Coupled Geometry Surface Coil for Small Mammal Whole Brain fMRI
Kyle Johnson, Hanbing Lu, Jason W. Sidabras·bioRxiv·Aug 7, 2026