bioRxivBiophysics
In situ structure determination using single particle cryo-electron microscopy images
Abstract
Cryo-electron microscopy (cryo-EM) tomography is a powerful tool for in situ structure determination. However, this method requires the acquisition of tilt series, and its time consuming throughput of acquiring tilt series severely slows determination of in situ structures. By treating the electron densities of non-target protein as non-Gaussian distributed noise, we developed a new target function that greatly improves the efficiency of the recognition of the target protein in a single cryo-EM image without acquiring tilt series. Moreover, we developed a sorting function that effectively eliminates the false positive detection, which not only improves the resolution during the subsequent structure refinement procedure but also allows using homolog proteins as models to recognize the target protein. Together, we developed an in situ single particle analysis (isSPA) method. Our isSPA method was successfully applied to solve structures of glycoproteins on the surface of a non-icosahedral virus and Rubisco inside the carboxysome. The cryo-EM data from both samples were collected within 24 hours, thus allowing fast and simple structural determination in situ.
- assay: cryo-EM
- research focus: protein structure prediction
- approach: deep learning
- approach: statistical model
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- MISO: Microfluidic protein isolation enables single particle cryo-EM structure determination from a single cell colony
Gangadhar Eluru, Steven De Gieter, … Rouslan G. Efremov·Nature MethodsPeer-reviewed·Nov 13, 2025
- Sub-3 A resolution structure of apoferritin using a multi-purpose TEM with a side-entry cryo-holder
Yoko Kayama, Raymond N. Burton‐Smith, … Kazuyoshi Murata·bioRxiv·Mar 24, 2020
- Obtaining high-resolution cryo-EM structures using a common LaB6, 120-keV electron microscope equipped with a sub 200-keV optimised direct electron detector.
Hariprasad Venugopal, Jesse I. Mobbs, … Georg Ramm·Science AdvancesPeer-reviewed·Jan 3, 2025
- VitisC: Visualizing interested target via integrated scaffold of cytoophidium
Boqi Yin, Huan-Huan Hu, … Ji‐Long Liu·bioRxiv·Jan 17, 2025
- Microfluidic protein isolation and sample preparation for high resolution cryo-EM
C. Schmidli, S. Albiez, … T. Braun·bioRxiv·Feb 21, 2019
- Mass-selective and ice-free cryo-EM protein sample preparation via native electrospray ion-beam deposition
Tim K. Esser, Jan Böhning, … Stephan Rauschenbach·PNAS NexusPeer-reviewed·Aug 6, 2022