No Strings Attached: Predicting Tricuspid Valve Deformation Without In Vivo Chordal Geometry
Mrudang MathuriD, Collin E. HaeseiD, Vijay K. DubeyiD, Sumedh Seetharam, William D. MeadoriD, Tomasz JaźwieciD, Natalie T. SimonianiD, Michael S. Sacks, Marcin MalinowskiiD, Jan N. FuhgiD, Issam Moussa, Joshua A. CoheniD, Matthew R. Summers, Tomasz A. TimekiD, William HiesingeriD, Manuel K. RauschiD
Abstract
Predictive biomechanical models of the tricuspid valve require accurate representation of the chordae tendineae, yet subject-specific chordal geometry is difficult to reconstruct from non-invasive imaging. Here, we adopt a framework for generating functionally equivalent synthetic chordae without prior knowledge of in vivo chordal attachments. To this end, we first adapt an anatomy-informed hyperelastic shape-matching method that establishes correspondence between end-diastolic and end-systolic leaflet configurations using chordal-mimicking forces, a rigid contact template, and a Gaussian-smoothed locally corrective pressure field. We then generate synthetic chordal insertion sites using zone-based rejection sampling and calibrate the unloaded length of each chord by combining reaction forces with the chordal stress-stretch relationship. The framework was evaluated using Texas TriValve 1.1, a high-fidelity finite element model of a human tricuspid valve validated against beating-heart echocardiography. We found that shape matching reproduced the target end-systolic geometry with a mean inter-surface distance of 0.29 {+/-} 0.35 mm. Moreover, synthetic chordal insertions faithfully reproduce end-systolic leaflet deformations. We subsequently examined synthetic chordal configurations containing 202, 225, and 450 insertions, informed by measurements from eight explanted human tricuspid valves. Here, increasing insertion number reduced mean inter-surface distance from 0.63 {+/-} 0.52 mm to 0.49 {+/-} 0.44 mm and reduced contact area errors from 3.52% to 0.59%. Across all configurations, mean maximum principal stretch errors in leaflet belly regions remained below 2.4%, while areal strain errors ranged from 0.34% to 10.01%. These results demonstrate that anatomically informed shape matching coupled with stress-based chordal calibration can reproduce tricuspid valve closure without explicit subject-specific chordal geometry. This framework provides a foundation for generating synthetic subvalvular anatomy for future imaging-derived, predictive tricuspid valve models.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- The Role of Secondary Chordae Tendineae in Mitral Valve Mechanics: A Benchtop Study
Roger Karl, Dominic P. Recco, … Peter E. Hammer·bioRxiv·Jul 27, 2026
- Understanding the Mechanisms Behind the Annuloplasty Effect in Tricuspid Valve TEER: A Computational Study
Collin E. Haese, Vijay K. Dubey, … Manuel K. Rausch·Journal of BiomechanicsPeer-reviewed·Jun 23, 2026
- Rt3DE-based finite element analysis of functional tricuspid regurgitation and RV free wall approximation
Davide Tondi, S. Vailetta, … Emiliano Votta·bioRxiv·Jul 14, 2026
- The Tricuspid Valve Maladapts in a Pulmonary Hypertension Rat Model
Chien-Yu Lin, Bogusław Gawęda, … Manuel K. Rausch·bioRxiv·Jul 12, 2026
- Tricuspid valve leaflet remodeling in sheep with biventricular heart failure: A comparison between leaflets
Colton J. Kostelnik, William D. Meador, … Manuel K. Rausch·Acta BiomaterialiaPeer-reviewed·Sep 20, 2024
- Cardiac hemodynamics computational modeling including chordae tendineae, papillaries, and valves dynamics
Lorenzo Bennati, Andrea Crispino, Christian Vergara·Computers in Biology and MedicinePeer-reviewed·Jan 25, 2025