Iris Crypts Could Reduce the Chance of Angle Closure: A Computational Biomechanics Study Derived from Clinical and Human Iris Data
Royston K. Y. TaniD, Tin A. TuniD, Fabian Albert BraeuiD, Shamira PereraiD, Michaël J. A. GirardiD
Abstract
PurposeTo investigate the effect of crypts during pupil constriction and dilation on the potential for angle closure by performing finite element analysis using clinical and experimental data on human tissues. MethodsA computational model was developed to determine the influence of small crypts (surface area of [~]0.015 mm2) and large crypts (surface area of 0.300 mm2) on the anterior chamber angles during pupil dilation. The model needed permeability data from human subjects, hence 21 enucleated human eyes (72 hours post-mortem) were procured and subjected to a flow set-up previously reported. Finally, 66 subjects were recruited to measure pupil constriction and dilation levels from optical coherence tomography (OCT) videos. ResultsThe hydraulic permeability of the human iris stroma was determined to be 2.55 {+/-} 1.93 x 10-5 mm2/Pa{middle dot}s. The average iris constriction and dilation durations were 0.710 {+/-} 0.213 seconds and 1.24 {+/-} 0.401 seconds, respectively, with pupil diameter changes of 1.16 {+/-} 0.39 mm and 0.75 {+/-} 0.27 mm, respectively. The computational models had starting anterior chamber angles of 51.30{degrees} and final anterior chamber angles of 26.81{degrees} once steady state has been reached. In an extreme case with decreased anterior border layer (ABL) permeability, the anterior chamber angle narrowed to 12.37{degrees}, but the presence of crypts kept the angle above 20.36{degrees}, highlighting the potential of crypts in preventing angle closure. ConclusionsOur findings on the biomechanics of crypts in the iris may drive the development of novel treatments by altering ABL morphology, providing an alternative bypass for angle closure prevention in high-risk patients.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 1
- FWCI
- 0.83
- Field percentile
- top 33%
- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Iris Morphological and Biomechanical Factors Influencing Angle Closure During Pupil Dilation
Royston K. Y. Tan, Gim Yew Ng, … Michaël J. A. Girard·Investigative Ophthalmology & Visual SciencePeer-reviewed·Sep 4, 2024
- Changes in Iris Stiffness and Permeability in Primary Angle Closure Glaucoma
S. K. Panda, R. K. Y. Tan, … M. J. A. Girard·bioRxiv·May 4, 2021
- In vivo Biomechanical Assessment of Iridial Deformations and Muscle Contractions in Human Eyes
B. N. Safa, M. R. Bahrani Fard, C. R. Ethier·bioRxiv·Jan 14, 2022
- The Structural Layers of the Porcine Iris Exhibit Inherently Different Biomechanical Properties
R. K. Y. Tan, S. K. Panda, … M. J. A. Girard·bioRxiv·Dec 11, 2022
- Experimental Assessment of Iris Water Content and Sex Differences in Mature Rabbits
Nima Rafezi, Sunaya Amrin Rahman, Babak N. Safa·bioRxiv·Sep 11, 2026
- The Effects of Negative Periocular Pressure on Biomechanics of the Optic Nerve Head and Cornea: A Computational Modeling Study
B. N. Safa, A. Bleeker, … C. R. Ethier·bioRxiv·May 17, 2022