Measurement force, speed and post-mortem time affect the ratio of CNS grey to white matter elasticity
Julia BeckeriD, Alexander K. WinkeliD, Eva KreysingiD, Kristian FranzeiD
Abstract
For several decades, many attempts have been made to characterise the mechanical properties of grey and white matter, which constitute the two main compartments of the central nervous system (CNS), with various methods and contradictory results. In particular, the ratio of grey-to-white-matter elasticity is sometimes larger than 1 and sometimes smaller; the reason for this apparent discrepancy is currently unknown. Here, we exploited atomic force microscopy (AFM)-based indentation measurements to systematically investigate how the measurement force, measurement speed, post-mortem interval and temperature affect the measured elasticity of spinal cord tissue, and in particular the ratio of grey-to-white-matter elasticity (Kg/Kw). Within the explored parameter space, increasing measurement force and speed increased the measured elasticity of both grey and white matter. However, Kg/Kw declined from values as high as [~]5 at low forces and speeds to [~]1 for high forces and speeds. Kg/Kw also strongly depended on the anatomical plane in which the measurements were conducted and was considerably higher in transverse sections compared to longitudinal sections. Furthermore, the post-mortem interval impacted both the absolute measured tissue elasticity and Kg/Kw. Grey matter elasticity started decreasing [~]3 hours post-mortem until reaching a plateau after [~]6 hours. In contrast, white matter elasticity started declining from the beginning of the measurements until [~]6 hours post-mortem, when it also levelled off. As a result, Kg/Kw increased until [~]6 hours post-mortem before stabilising. Between 20{degrees}C and 38{degrees}C, both grey and white matter elasticity decreased at a similar rate, without affecting Kg/Kw. We have thus identified differences in the response of grey and white matter to varying strains and strain rates, and the post-mortem interval, and excluded temperature as a factor affecting Kg/Kw. These differential responses likely contribute to the contradictory results obtained with different methods working in different strain regimes. Statement of significanceWe here showed that the mechanical response of CNS grey and white matter to an applied force differentially depends on measurement parameters such as the speed and magnitude of the applied forces, the post-mortem interval, as well as the anatomical axis along which measurements are conducted. These results broaden our understanding of CNS mechanics and pave the way for better and more targeted experimental design of future experiments. Ultimately, they may help to reconcile seemingly contradictory results in the literature concerning the ratio of grey-to-white-matter elasticity.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 2
- FWCI
- 0.48
- Field percentile
- top 48%
- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Spatial scale of indentation explains shift in ratio between spinal cord gray and white matter stiffness
Oskar Fabian Neumann, Harsh Vardhan Surana, … Silvia Budday·Scientific ReportsPeer-reviewed·Jun 2, 2026
- Mechanical Properties of White Matter Tracts in Aging Assessed via Anisotropic MR Elastography
Diego A. Caban-Rivera, Letitia Williams, … Curtis L. Johnson·Imaging NeurosciencePeer-reviewed·Jan 1, 2026
- The white matter fiber tract deforms most in the perpendicular direction during in vivo volunteer impacts
Zhou Zhou, Christoffer Olsson, … Svein Kleiven·Journal of NeurotraumaPeer-reviewed·Aug 30, 2024
- In situ impedance measurements on postmortem porcine brain
Lucas Poßner, Matthias Laukner, … Konstantin Weise·Current Directions in Biomedical EngineeringPeer-reviewed·Sep 1, 2020
- Effect of Neck Muscle Strength and Passive Cervical Viscoelasticity on Regional Brain and Axonal Tissue Response
Suman Kanti Chowdhury·bioRxiv·Oct 29, 2026
- Effect of contact pressure on porcine postmortem brain tissue impedance
Lucas Poßner, Florian Wilhelmy, … Dirk Lindner·bioRxiv·Aug 4, 2022