Image quality metrics fail to accurately represent biological information in fluorescence microscopy
Ihuan GunawaniD, Richard J. MarshiD, Nandini AggarwaliD, Erik H. W. MeijeringiD, Susan CoxiD, John George LockiD, Siân CulleyiD
Abstract
Image processing methods offer the potential to improve the quality of fluorescence microscopy data, allowing for image acquisition at lower, less phototoxic illumination doses. The training and evaluation of such methods is informed and driven by full-reference image quality metrics (IQMs); however, these metrics derive from applications to natural scene images, not fluorescence microscopy images. Here we investigate the response of IQMs to common properties of fluorescence microscopy data and whether IQMs are capable of reporting the biological information content of images. We find that IQM scores are biased by image content for both raw and processed microscopy data, and that improvements in IQM values reported after processing are not reliably correlated with performance in downstream analysis tasks. As common IQMs are unreliable proxies for guiding image processing developments in biological fluorescence microscopy, image processing performance should be benchmarked according to downstream analysis success.
- Citations
- 4
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Monitoring microscope performance in an imaging facility using OMERO-metrics.
Sophia Sommer, Oumou Dhmine, … Ian M. Dobbie·bioRxiv·Jul 1, 2026
- Long-term quality assessment and monitoring of light microscope performance through accessible and reliable protocols, tools and metrics
O. Faklaris, L. Bancel-Vallee, … T. Guilbert·bioRxiv·Jun 16, 2021
- Quality-control Normalization of Fluorescence Microscopy Morphometry and Colocalization Measurements for Improved Accuracy and Cross-instrument Reproducibility
John Oreopoulos, Glyn Nelson, … Bernhard Goetze·bioRxiv·Oct 9, 2025
- On doubting image quality assessment metrics for microscopy virtual staining
Wei-shan Li, Gregory P. Way·bioRxiv·Sep 4, 2026
- Content-Aware Image Restoration: Pushing the Limits of Fluorescence Microscopy
MARTIN G. WEIGERT, Uwe Schmidt, … Eugene Wimberly Myers·Nature MethodsPeer-reviewed·Nov 19, 2018
- Quanta microscopy enables fluorescence imaging at the native bit-plane rate
Jooyeong Yun, Keyi Han, … Shu Jia·bioRxiv·Oct 28, 2026