Sign in
BiophysicsbioRxiv
Preprint

Comparison of tri-exponential decay vs. bi-exponential decay and full fitting vs. segmented fitting for modeling liver intravoxel incoherent motion diffusion MRI

Olivier Chevallier, Nan Zhou, Jean-Pierre Cercueil, Jian He, Romaric Loffroy, Yì Xiáng J. Wáng

Abstract

PurposeTo determine whether bi- or tri-exponential models, and full or segmented fittings, better fit IVIM imaging signal of healthy livers.\n\nMaterials and methodsDiffusion-weighted images were acquired with a 3-T scanner using respiratory-triggered echo-planar sequence and 16 b-values (0[~]800 s/mm2). Eighteen healthy volunteers had liver scanned twice in the same session, and then once again in another session. Region of interest (ROI)-based measurements were processed with bi-exponential model full fitting and segmented fitting (threshold b-value = 80 s/mm2), as well as tri-exponential model full fitting and segmented fitting (threshold b-value = 200 s/mm2).\n\nResultsWith all scans signal averaged, bi-exponential model full fitting showed Dslow=1.14, Dfast=193.6x10-3 mm2/s, and PF=16.9%, and segmented fitting showed Dslow=1.03, Dfast=56.7x10-3 mm2/s, and PF=21.3%. IVIM parameters derived from tri-exponential model were similar for full fitting and segmented fitting, with a slow (Dslow=0.98x10-3 mm2/s; Fslow=76.4 or 76.6%), a fast (Dfast=15.1 or 15.4x10-3 mm2/s; Ffast=11.8 or 11.7%) and a very fast (DVfast=445.0 or 448.8x10-3 mm2/s; FVfast=11.8 or 11.7 %) diffusion compartments. Tri-exponential model provided an overall better fit than bi-exponential model. For bi-exponential model, full fitting provided better fit at very low and low b-values compared with segmented fitting with the later tended to underestimate Dfast, however, segmented method demonstrated lower error in signal prediction for high b-values. Compared with full fitting, tri-exponential segmented fitting offered better scan-rescan reproducibility.\n\nConclusionFor healthy liver, tri-exponential modelling is preferred than bi-exponential modelling. For bi-exponential model, segmented fitting underestimates Dfast, but offers more accurate estimation of Dslow.

PDFDOI

02 /Specification & Classification

Click any tag to browse matching papers

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.

Similarity Map
SelectedSame fieldCross-field
THISXiao '21Li '17Wang '17Chevallier '17Huang '20Stabinska '22
66% semantic matchBiophysics
B.-H. Xiao, Y.-X. Wang·bioRxiv·Mar 11, 2021