Scientific ReportsBiophysicsPeer-reviewed journal article
Fluorescent Sp3 Defect-Tailored Carbon Nanotubes Enable NIR-II Single Particle Imaging in Live Brain Slices at Ultra-Low Excitation Doses
A. K. Mandal, X. Wu, J. S. Ferreira, M. Kim, L. R. Powell, H. Kwon, L. Groc, Y. Wang, L. Cognet
Abstract
Cellular and tissue imaging in the second near-infrared window (NIR-II, [~]1000 - 1350 nm) is advantageous for in vivo studies because of low light extinction by biological constituents at these wavelengths. However, deep tissue imaging at the single molecule sensitivity has not been achieved in the NIR-II window due to lack of suitable bio-probes. Single-walled carbon nanotubes have emerged as promising near-infrared luminescent molecular bio-probes; yet, their inefficient photoluminescence (quantum yield [~]1%) drives requirements for sizeable excitation doses ([~]1-10 kW/cm2) that are significantly blue-shifted from the NIR-II region (<850 nm) and may thus ultimately compromise live tissue. Here, we show that single nanotube imaging can be achieved in live brain tissue using ultralow excitation doses ([~]100 W/cm2), an order of magnitude lower than those currently used. To accomplish this, we synthesized fluorescent sp3-defect tailored (6,5) carbon nanotubes which, when excited at their first order excitonic transition fluoresce brightly at [~]1160 nm. The biocompatibility of these functionalized nanotubes, which are wrapped by state-of-the-art encapsulation agents (phospholipid-polyethylene glycol), is demonstrated using standard cytotoxicity assays. Single molecule photophysical studies of these biocompatible nanotubes allowed us to identify the optimal luminescence properties in the context of biological imaging.
- organism: mouse
- assay: imaging
- assay: fluorescence / live-cell microscopy
- research focus: imputation
- research focus: cell type annotation
- approach: experimental assay
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Ultrabright NIR-II Nanoprobes for Ex Vivo Bioimaging: Protein Nanoengineering Meets Molecular Engineering
Isabella Vasquez, Asma Harun, … Indrajit Srivastava·ACS Nanoscience AuPeer-reviewed·Oct 6, 2025
- Non-Invasive Confocal Fluorescence Imaging of Mice Beyond 1700 nm Using Superconducting Nanowire Single-Photon Detectors
- Perfecting and extending the near-infrared biological window
- Self-confocal NIR-II fluorescence microscopy for in vivo imaging
- Near Infrared-II Fluorescent protein for In-vivo Imaging
Q. Sun·bioRxiv·Mar 4, 2022
- Molecular Recognition of Dopamine with Dual Near Infrared Excitation-Emission Two-Photon Microscopy
Jackson Travis Del Bonis-O’Donnell, Ralph H. Page, … Markita Patricia Landry·bioRxiv·Jul 19, 2017