Mechanical effects of MitraClip on leaflet stress and myocardial strain in functional mitral regurgitation: A finite element modeling study.
Y. Zhang, V. Y. Wang, A. E. Morgan, J. Kim, M. D. Handschumacher, C. S. Moskowitz, R. A. Levine, L. Ge, J. M. Guccione, J. W. Weinsaft, M. B. Ratcliffe
Abstract
PurposeMitraClip is the sole percutaneous device approved for functional mitral regurgitation (MR; FMR) but MR recurs in over one third of patients. As device-induced mechanical effects are a potential cause for MR recurrence, we tested the hypothesis that MitraClip increases leaflet stress and procedure-related strain in sub-valvular left ventricular (LV) myocardium in FMR associated with coronary disease (FMR-CAD).\n\nMethodsSimulations were performed using finite element models of the LV + mitral valve based on MRI of 5 sheep with FMR-CAD. Models were modified to have a 20% increase in LV volume ({uparrow}LV_VOLUME) and MitraClip was simulated with contracting beam elements (virtual sutures) placed between nodes in the center edge of the anterior (AL) and posterior (PL) mitral leaflets. Effects of MitraClip on leaflet stress in the peri-MitraClip region of AL and PL, septo-lateral annular diameter (SLAD), and procedure-related radial strain (Err) in the sub-valvular myocardium were calculated.\n\nResultsMitraClip increased peri-MitraClip leaflet stress at end-diastole (ED) by 22.3{+/-}7.1 kPa (p<0.0001) in AL and 14.8{+/-}1.2 kPa (p<0.0001) in PL. MitraClip decreased SLAD by 6.1{+/-}2.2 mm (p<0.0001) and increased Err in the sub-valvular lateral LV myocardium at ED by 0.09{+/-}0.04 (p<0.0001)). Furthermore, MitraClip in {uparrow}LV_VOLUME was associated with persistent effects at ED but also at end-systole where peri-MitraClip leaflet stress was increased in AL by 31.9{+/-}14.4 kPa (p=0.0268) and in PL by 22.5{+/-}23.7 kPa (p=0.0101).\n\nConclusionsMitraClip for FMR-CAD increases mitral leaflet stress and radial strain in LV sub-valvular myocardium. Mechanical effects of MitraClip are augmented by LV enlargement.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- A novel MRI-based finite element modeling method for calculation of myocardial ischemia effect in patients with functional mitral regurgitation.
Y. Zhang, V. Y. Wang, … M. B. Ratcliffe·bioRxiv·Oct 29, 2019
- 3D Contractile and Remodeling Behaviors of Functionally Normal and Prolapsed Human Mitral Valve Interstitial Cells
Toni M. West, Gabriel Peery, … Michael S. Sacks·Annals of Biomedical EngineeringPeer-reviewed·Aug 3, 2026
- Transcatheter Edge-to-Edge Repair Increases Annular Forces in In Vitro Whole Heart Preparations
Collin E. Haese, Trace G. LaRue, … Manuel K. Rausch·bioRxiv·Mar 5, 2026
- The Role of Secondary Chordae Tendineae in Mitral Valve Mechanics: A Benchtop Study
Roger Karl, Dominic P. Recco, … Peter E. Hammer·bioRxiv·Jul 27, 2026
- Mitral valve leaflet response to ischemic mitral regurgitation: From gene expression to tissue remodeling
D. P. Howsmon, B. V. Rego, … M. S. Sacks·bioRxiv·Dec 6, 2019
- Contributions of mechanical loading and hormonal changes to eccentric hypertrophy during volume overload: a Bayesian analysis using logic-based network models.
Johane Bracamonte, Lionel D. Watkins, … Jeffrey W. Holmes·PLoS Computational BiologyPeer-reviewed·Apr 16, 2025