bioRxivBioengineeringPreprint
Transcatheter Edge-to-Edge Repair Increases Annular Forces in In Vitro Whole Heart Preparations
Collin E. HaeseiD, Trace G. LaRueiD, Diego GuajardoiD, Campbell HarknessiD, William HiesingeriD, Jan N. FuhgiD, Tomasz A. TimekiD, Manuel K. RauschiD
Abstract
BackgroundTricuspid transcatheter edge-to-edge repair (TEER) can induce an acute annuloplasty effect. While this has a therapeutic benefit, the mechanisms driving the reduction in annular size remain unclear. ObjectivesWe quantify the annular force induced by TEER in vitro in whole porcine heart preparations. We explore the impact of clipping different leaflet pairs on the TEER-induced annular forces. MethodsWe performed 49 interventions in 13 porcine hearts using a MitraClip XT. The clip was implanted between either the anterior-septal (AS), anterior-posterior (AP), or posterior-septal (SP) leaflet pairs. We also considered two-clip interventions between the combination of the AS-AP, AS-PS, or AP-PS leaflet pairs. For each intervention, we measured the right ventricular pressure, transvalvular flow rate, and force at eight locations around the annulus. ResultsTEER induced significant inward-pulling forces on the annulus. The maximum force was induced following an AS-PS two-clip intervention. A single AS clip induced the largest force among the one-clip interventions. Furthermore, the AP and AS-AP interventions induced the smallest annular forces. ConclusionsThe magnitude of the TEER-induced force depends on the intervention and number of clips implanted.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Understanding the Mechanisms Behind the Annuloplasty Effect in Tricuspid Valve TEER: A Computational Study
Collin E. Haese, Vijay K. Dubey, … Manuel K. Rausch·Journal of BiomechanicsPeer-reviewed·Jun 23, 2026
- Effect of Clover versus Zipping on Annular Geometry and Dynamics in Tricuspid Edge-to-Edge Repair
Magda Piekarska, Tomasz Stącel, … Tomasz A. Timek·bioRxiv·Oct 28, 2026
- Mechanical effects of MitraClip on leaflet stress and myocardial strain in functional mitral regurgitation: A finite element modeling study.
Y. Zhang, V. Y. Wang, … M. B. Ratcliffe·bioRxiv·Jun 30, 2019
- The Role of Secondary Chordae Tendineae in Mitral Valve Mechanics: A Benchtop Study
Roger Karl, Dominic P. Recco, … Peter E. Hammer·bioRxiv·Jul 27, 2026
- Cardiac unloading via a transvalvular pump prevents arrhythmias following myocardial ischemia / reperfusion by preserving coronary microcirculation and cardiomyocyte nanostructure
Madison Ammon, Pedro Melo, … Rengasayee Veeraraghavan·bioRxiv·Oct 29, 2026
- Auxetic patch material exhibits systolic thickening and restores pump function in a finite element model of acute myocardial infarction repair
J. Borrello, Z. Zheng, … K. D. Costa·bioRxiv·Nov 2, 2023