bioRxivBioengineeringPreprint
Towards genuine three-dimensional diffusion imaging with physiological motion compensation
Yishi WangiD, Dehe WengiD, Jieying ZhangiD, Tianyi QianiD, Wenzhang LiuiD, Kun ZhouiD, Yanglei Wu, Baogui ZhangiD, Qing Li, Jing JingiD, Zhe ZhangiD
Abstract
PurposeWe aim to implement a 3D DWI sequence and show its usage on patients with new ischemic lesions. Materials and MethodsThe proposed 3D DWI sequence was implemented by integrating second-order gradient moment nulling (M2) and cardiac motion synchronization (Sync). All data were acquired on a 3T MAGNETOM Prisma scanner (Siemens Healthcare, Erlangen, Germany) using a 64 channel head and neck coil. 21 healthy volunteers underwent 3D DWI scans at 0.9 mm isotropic resolution using four motion compensation methods for comparison: no compensation (M0), M2 only, Sync only and the proposed M2+Sync method. 2D phase variation maps with different motion compensation methods were also acquired for one subject to illustrate the mechanism of the proposed method. A ghost-to-signal ratio (GSR) and blurring index was defined and compared among the four methods with repeated measures ANOVA and Tukeys test. 3D DWI was compared with 2D DWI for ADC quantification. Image quality and ischemic lesion conspicuity were evaluated with 12 patients after endovascular treatment. >ResultsWhole brain 3D DWI was achieved at 0.9 mm isotropic resolution within 5 minutes using the proposed sequence. M2+Sync achieved the lowest level of GSR and blurring along the slice direction. ADC quantification showed no statistically significant difference between M2+Sync compared to 2D DWI. 3D DWI showed similar image quality, higher lesion conspicuity and counts compared to 2D DWI. ConclusionDirect 3D DWI can be achieved by the combination of second order gradient moment nulling and cardiac synchronization.
- Citations
- 1
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- ZOnally magnified Oblique Multi-slice (ZOOM) for cardiac diffusion weighted imaging in vivo
Lars Mueller, Sam Coveney, … Jürgen E. Schneider·bioRxiv·Sep 20, 2025
- Anisotropy Measure from Three Diffusion-Encoding Gradient Directions
Santiago Aja‐Fernández, Guillem París, … Antonio Tristán‐Vega·Magnetic Resonance ImagingPeer-reviewed·Feb 2, 2022
- Modelling motion-induced signal corruption in steady-state diffusion MRI
Benjamin C. Tendler, Wenchuan Wu, … Aaron T. Hess·Magnetic Resonance in MedicinePeer-reviewed·Feb 27, 2026
- Artifacts can be deceiving: The actual location of deep brain stimulation electrodes differs from the artifact seen on magnetic resonance images
Noa B Nuzov, Bhumi Bhusal, … Laleh Golestanirad·Stereotactic and Functional NeurosurgeryPeer-reviewed·Dec 16, 2022
- PreQual: An automated pipeline for integrated preprocessing and quality assurance of diffusion weighted MRI images
L. Y. Cai, Q. Yang, … B. A. Landman·bioRxiv·Sep 14, 2020
- Do you see what I see? Diffusion imaging protocol heterogeneity biases ischemic core volume, location, and clinical associations in acute stroke
Jonathan Rafael‐Patiño, Elda Fischi-Gómez, … Jonas Richiardi·bioRxiv·Mar 19, 2024