High-frame-rate analysis of knee cartilage deformation by spiral dualMRI and relaxation mapping
W. Lee, E. Miller, H. Zhu, C. Luetkemeyer, S. E. Schneider, C. Neu
Abstract
PurposeDaily activities including walking impose high frequency cyclic forces on cartilage and repetitive compressive deformation. Analyzing cartilage deformation during walking would provide spatial maps of displacement, strain, and enable viscoelastic characterization, which may serve as imaging biomarkers for early cartilage degeneration when the damage is still reversible. However, the time-dependent biomechanics of cartilage is not well described, and how defects in the joint impact the viscoelastic response is unclear. MethodsWe used spiral acquisition with displacement encoding MRI to quantify displacement and strain maps at a high frame rate (40 ms; 25 frames/sec) in tibiofemoral joints. We also employed relaxometry methods (T1, T1{rho}, T2, T2*) on the cartilage. ResultsNormal and shear strains were concentrated on the tibiofemoral contact area during loading, and the defected joint exhibited larger compressive strains. We also determined a positive correlation between the change of T1{rho} in cartilage after cyclic loading and increased compressive strain on the defected joint. Viscoelastic behavior was quantified by the time-dependent displacement, where the damaged joint showed increased creep behavior compared to the intact. ConclusionsOur results indicate that spiral scanning with displacement encoding can quantitatively differentiate the damaged from intact joint using the strain and creep response. The viscoelastic response identified with this methodology could serve as biomarkers to detect defects in joints in vivo and facilitate the early diagnosis of joint diseases such as osteoarthritis.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Multi-frame biomechanical and relaxometry analysis during in vivo loading of the human knee by spiral dualMRI and compressed sensing
W. Lee, E. Miller, … C. P. Neu·Magnetic Resonance in MedicinePeer-reviewed·May 22, 2023
- Intervertebral Disc Elastography to Relate Shear Modulus and Relaxometry in Compression and Bending
Z. R. Davis, P. C. Gossett, … D. D. Chan·bioRxiv·Sep 1, 2023
- Associations of human femoral condyle cartilage structure and composition with viscoelastic and constituent-specific material properties at different stages of osteoarthritis
M. Ebrahimi, A. Turkiewicz, … P. Tanska·bioRxiv·May 1, 2022
- A musculoskeletal finite element model of rat knee joint for evaluating cartilage biomechanics during gait
G. A. Orozco, K. Karjalainen, … R. K. Korhonen·bioRxiv·Sep 1, 2021
- In situ profiling of nanoscale displacements uncovers mechano-architectural predictors of osteoarthritis emergence
Aikta Sharma, Lucinda Evans, … Katherine Ann Staines·bioRxiv·Dec 8, 2025
- High spatial resolution analysis using indentation mapping differentiates biomechanical properties of normal vs. degenerated mouse articular cartilage
A. O. Masson, B. Besler, … R. J. Krawetz·bioRxiv·Oct 26, 2021