Noninvasive detection of Phenylalanine in the human brain with MRS at 7T
Abstract
We set out to measure phenylalanine in the human brain using magnetic resonance spectroscopy (MRS) in a ultra-high field 7T MRI scanner. Phenylalanine is a precursor to Norepinephrine, a neurotransmitter important for attention and arousal. Depletion in norepinephrine, especially in the locus coeruleus, has been implicated as an etiological factor in Alzheimers disease. Therefore, being able to noninvasively measure phenylalanine in vivo in humans has a multitude of translational applications. Using phantom experiments, we first validate and optimize the MRS techniques used for observing phenylalanine in the brain at 7T. However, we failed to detect phenylalanine in human volunteers (N=15). In order to understand the reasons for this failure, we performed experiments in a cat model with external phenylalanine injections to determine the amount of phenylalanine required for it to be detected in vivo in the brain. This threshold was found to be 3.4 mM. This indicated that phenylalanine concentrations in both healthy and AD patients, that too in a small region such as the locus coeruleus, will likely not meet this threshold. Therefore, we conclude that even with state-of-the-art technologies and 7T MRI, it is not possible to detect phenylalanine in the human brain in vivo under natural conditions.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- Organism
- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- In vivo multi-parametric manganese-enhanced MRI for detecting senile plaques in rodent models of Alzheimer's disease
Eugene Kim, Davide Di Censo, … Diana Cash·Scientific ReportsPeer-reviewed·Jun 14, 2021
- Mapping of Glutamate Metabolism using 1H FID-MRSI after oral Administration of Glc at 9.4 T
Theresia Ziegs, Loreen Ruhm, … A Henning·NeuroImagePeer-reviewed·Feb 12, 2023
- In vivo quantification of creatine kinase kinetics in mouse brain using 31P-MRS at 7 Tesla
Mohamed Tachrount, Sean Smart, … Antoine Cherix·bioRxiv·Sep 9, 2024
- Mapping prion pathology in mice using quantitative imaging: an MRI study
E. Demetriou, M. Tachrount, … X. Golay·bioRxiv·Dec 28, 2021
- Off-resonance saturation as an MRI method to quantify ferritin-bound iron in the post-mortem brain
L. Bossoni, I. Hegeman-Kleinn, … L. van der Weerd·bioRxiv·Mar 22, 2021
- Lipid suppressed and tissue-fraction corrected metabolic distributions in human central brain structures using 2D 1H Magnetic Resonance Spectroscopic Imaging at 7 tesla
Alex A. Bhogal, Tommy A.A. Broeders, … Jannie P. Wijnen·Brain and BehaviorPeer-reviewed·Nov 20, 2020