bioRxivBioengineeringPreprint
Development of a shortwave infrared (SWIR) sinuscope for the detection of cerebrospinal fluid (CSF) leaks
T. W. Klein, S. Yang, M. A. Tusty, J. V. Nayak, M. T. Chang, O. T. Bruns, T. S. Bischof, T. A. Valdez
Abstract
SignificanceCSF rhinorrhea (leakage of brain fluid from the nose) can be difficult to identify and currently requires invasive procedures such as intrathecal fluorescein which requires a lumbar drain placement. Fluorescein is also known to have rare but significant side effects including seizures and death. As the number of endonasal skull base cases increase, the number of CSF leaks have also increased for which an alternative diagnostic method would be highly advantageous to patients. AimTo develop an instrument to identify CSF leaks based on water absorption in the SWIR without the need of intrathecal contrast agents. This device needed to be adapted to the anatomy of the human nasal cavity while maintaining low weight and ergonomic characteristics of current surgical instruments. ApproachAbsorption spectra of CSF and artificial CSF were obtained to characterize the absorption peaks that could be targeted with SWIR light. Different illumination systems were tested and refined prior to adapting them into a portable endoscope for testing in 3D printed models and cadavers for feasibility. ResultsWe identified CSF to have an identical absorption profile as water. In our testing, a narrow band laser source at 1480nm proved superior to using a broad 1450 nm LED. Using a SWIR enabling endoscope set up, we tested the ability to detect artificial CSF in a cadaver model. ConclusionsAn endoscopic system based on SWIR narrow band imaging can provide an alternative in the future to invasive methods of CSF leak detection.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Non-Invasive Confocal Fluorescence Imaging of Mice Beyond 1700 nm Using Superconducting Nanowire Single-Photon Detectors
- Shortwave Infrared Fluorescence Imaging with the Clinically Approved Near-Infrared Dye Indocyanine Green
J. A. Carr, D. Franke, … O. T. Bruns·bioRxiv·Apr 28, 2017
- Fluorescence visualization of deep-buried hollow organs
- Theranostic cranial implant for hyperspectral light delivery and microcirculation imaging without scalp removal
N. Davoodzadeh, M. S. Cano-Velazquez, … G. Aguilar·bioRxiv·Jul 31, 2019
- Quantifying brain-wide cerebrospinal fluid flow dynamics using slow-flow-sensitized phase-contrast MRI
Zijing Dong, Fuyixue Wang, … Jon̈athan R. Polimeni·bioRxiv·Mar 22, 2025
- Image Analysis Techniques for In Vivo Quantification of Cerebrospinal Fluid Flow
Dae‐Hyun Kim, Yiming Gan, … Jeffrey Tithof·Experiments in FluidsPeer-reviewed·Oct 30, 2023