bioRxivBioengineeringPreprint
Reconstruction of critical-sized mandibular defects in a sheep model using a PLLA-PGA-CC scaffold
Katharina PippichiD, Vincent Vitus KlettiD, Adem Aksu, Frank Reinauer, Stefan MilziD, Andreas M. Fichter, Lucas Maximilian RitschliD, Judith ReiseriD, Julia WerneriD, Christine M. BaumgartneriD, Achim von BomhardiD
Abstract
IntroductionCritical-sized bone defects cannot heal spontaneously, requiring additional, often burdensome, treatment. Thus, various synthetic substitute materials have been investigated regarding their treatment capacity. Poly-L-lactic acid (PLLA) and polyglycolic acid (PGA) have emerged as promising biodegradable scaffold materials. The addition of inorganic materials such as calcium carbonate (CC) has also been shown to be advantageous. This study investigates the effect on bone regeneration of PLLA-PGA-CC scaffolds in critical-sized bone defects over a two-year observation period using sheep as an animal model. MethodsCritical-sized mandible angle defects were created in twelve female merino sheep. Mandibular defects were reconstructed with PLLA-PGA-CC scaffolds in four sheep, while the remaining eight served as negative control (defects left empty). The scaffolds were manufactured using computer-aided design and manufacturing, incorporating an interconnected porous structure and fixated with polyether ether ketone cages. Bone regeneration was evaluated using computed tomography (CT) imaging at 3, 12, and 24 months postoperatively. Bone volume was assessed quantitatively. Additionally, a histological analysis was performed. ResultsSurgical procedures were successful and without major complications. CT assessment showed more bone regeneration in the scaffold group (mean volume: 7,472 mm3) than in the control group (4,168 mm3, p = 0.1) at 24 months postoperatively. Resorption of the scaffolds and formation of compact lamellar bone tissue were confirmed by histological analysis. However, the osteoconductive properties of the scaffolds were limited, with only minimal ingrowth of bone tissue into the porous structure. In both groups, fibrous tissue infiltration and the formation of cyst-like cavities in the defect region were observed. ConclusionPLLA-PGA-CC scaffolds were found to be biocompatible and enhanced bone regeneration compared to the control group. Due to fibrous tissue infiltration and the lack of osteoconductivity, the suitability of the material for critical-sized bone defect reconstruction is limited.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- 3D-printed polymeric scaffolds with optimized architecture to repair a sheep metatarsal critical-size bone defect
C. GAROT, S. Schoffit, … C. PICART·bioRxiv·Dec 14, 2022
- Resorbable Poly-(D,L)-Lactide Anchorage of Nanoparticulate Mineralized Collagen Materials Maximizes In Vivo Skull Regeneration
Meiwand Bedar, Xiaoyan Ren, … Justine C. Lee·bioRxiv·Jul 6, 2025
- 3D printed scaffold combined to 2D osteoinductive coatings to repair a critical-size mandibular bone defect
- Bioactive coatings on 3D printed polycaprolactone scaffolds for bone regeneration: a novel murine femur defect model for examination of the biomaterial capacity for repair.
K. M. Marshall, J. P. Wojciechowski, … R. O. C. Oreffo·bioRxiv·Dec 15, 2023
- Repair of critical-size porcine craniofacial bone defects using a collagen-polycaprolactone composite biomaterial
M. J. Dewey, D. J. Milner, … B. Harley·bioRxiv·Apr 19, 2021
- Reconstruction of Bone Defect Based on the Fusion of Osteoblasts and MSM/HA/PLGA Porous Scaffolds