bioRxivBioengineering
Towards A Wireless Image Sensor for Real-Time Fluorescence Microscopy in Cancer Therapy
R. Rabbani, H. Najafiaghdam, M. L. Roschelle, E. P. Papageorgiou, B. R. Zhao, M. M. Ghanbari, R. Muller, V. Stojanovic, M. Anwar
Abstract
We present a mm-sized, ultrasonically powered lensless CMOS image sensor as a progress towards wireless fluorescence microscopy. Access to biological information within the tissue has the potential to provide insights guiding diagnosis and treatment across numerous medical conditions including cancer therapy. This information, in conjunction with current clinical imaging techniques that have limitations in obtaining images continuously and lack wireless compatibility, can improve continual detection of multicell clusters deep within tissue. The proposed platform incorporates a 2.4x4.7 mm2 integrated circuit (IC) fabricated in TSMC 0.18 m, a micro laser diode (LD), a single piezoceramic and off-chip storage capacitors. The IC consists of a 36x40 array of capacitive trans-impedance amplifier-based pixels, wireless power management and communication via ultrasound and a laser driver all controlled by a Finite State Machine. The piezoceramic harvests energy from the acoustic waves at a depth of 2 cm to power up the IC and transfer 11.5 kbits/frame via backscattering. During Charge-Up, the off-chip capacitor stores charge to later supply a high-power 78 mW LD during Imaging. Proof of concept of the imaging front end is shown by imaging distributions of CD8 T-cells, an indicator of the immune response to cancer, ex vivo, in the lymph nodes of a functional immune system (BL6 mice) against colorectal cancer consistent with the results of a fluorescence microscope. The overall system performance is verified by detecting 140 m features on a USAF resolution target with 32 ms exposure time and 389 ms ultrasound backscattering.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Multicolor fluorescence microscopy for surgical guidance using a chip-scale imager with a low-NA fiber optic plate and a multi-bandpass interference filter
M. L. Roschelle, R. Rabbani, … M. Anwar·bioRxiv·Oct 16, 2023
- A dual-mode mobile phone microscope using the onboard camera flash and ambient light
A. Orth, E. R. Wilson, … B. C. Gibson·bioRxiv·Aug 18, 2017
- Image Scanning Microscopy with Single-Photon Detector Array
M. Castello, G. Tortarolo, … G. Vicidomini·bioRxiv·Jun 2, 2018
- High-speed compressed-sensing fluorescence lifetime imaging microscopy of live cells
- Non-Invasive Confocal Fluorescence Imaging of Mice Beyond 1700 nm Using Superconducting Nanowire Single-Photon Detectors
- In vivo fluorescence imaging with a flat, lensless microscope
Jesse K. Adams, Dong Yan, … Jacob T. Robinson·Nature Biomedical EngineeringPeer-reviewed·Mar 7, 2022