Population-level emulation enables fast Bayesian calibration of cardiac digital twins
Clara E. JonesiD, Felix E. PlappertiD, Derek J. BivonaiD, Johane H. BracamonteiD, Zarif Hossain, Isabella Aleman, Lyna Luu, Kenneth C. BilchickiD, Pim J.A. OomeniD
Abstract
Purpose: Patient-specific cardiac digital twins have the potential to guide individualized therapy, but generating these in a routine clinical workflow remains challenging. This is especially true when the twins must carry quantified uncertainty: Bayesian calibration requires thousands of simulations per patient, and the emulators that reduce this cost are typically trained one patient at a time. We aimed to train a single emulator across a patient cohort, so that a new patient can be calibrated in minutes without new simulations. Methods: We trained a population-level Gaussian process emulator whose inputs included a 12-dimensional latent encoding of the clinical features of each patient, so that a single emulator represents the whole cohort. We compared spending simulation budgets on resampling the real cohort with augmenting the cohort with digital chimeras, synthetic patients interpolated between real patients. Seven parameters of a closed-loop heart and circulation model were calibrated by Markov chain Monte Carlo to ten clinical biomarkers in 26 patients with left bundle branch block, each using an emulator trained without that patient, and the calibrated posteriors were compared against the full simulator. Results: A single emulator, trained without the held-out patient, calibrated the digital twin of each patient in 59.7-63.0 s per patient, versus 15 h with the simulator. Resampling the real cohort was the more efficient training strategy, bringing every output to R2 greater than or equal to 0.9, which augmentation did not achieve for the same simulation budget. For held-out patients, both strategies performed comparably (median leave-one-out normalized root-mean-square error 11.0% vs. 10.7%; p = 0.745), and error rose with distance from the cohort centroid (Spearman rho = +0.406). The calibrated models showed no cohort-wide bias (median standardized residual -0.12 against the clinical targets), and 95% predictive intervals contained 78.5% of targets, with the largest misfit in systolic blood pressure. Conclusion: Removing the need for new simulations for every new patient is a meaningful step toward uncertainty-aware cardiac digital twins that fit within a routine clinical workflow. Because the simulator, surrogate and sampler are interchangeable, the approach used here can be applied to other (cardiac) models and cohorts.
02 /Specification & Classification
Click any tag to browse matching papers- Organism
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Probabilistic Cardiac Digital Twins for Robust Patient-Specific Modeling
Dimitris G. Giovanis, K Zhang, … Natalia A. Trayanova·bioRxiv·May 12, 2026
- Digital twinning of cardiac electrophysiology for congenital heart disease
Matteo Salvador, Fanwei Kong, … Alison Lesley Marsden·Journal of The Royal Society InterfacePeer-reviewed·Jun 1, 2024
- Calibration and validation strategy for electromechanical cardiac digital twins
Zhinuo Jenny Wang, Maxx Holmes, … Blanca Rodríguez·bioRxiv·Mar 6, 2025
- Neural Network Guided Calibration for Fast Virtual Twin Generation in Cardiovascular ODE Models
Manuel Teixeira Cabeleira, Samiran Ray, … Vanessa Díaz‐Zuccarini·bioRxiv·May 8, 2026
- Uncertainty in cardiovascular digital twins despite non-normal errors in 4D flow MRI: identifying reliable biomarkers such as ventricular relaxation rate
Kajsa Tunedal, Tino Ebbers, Gunnar Cedersund·Computers in Biology and MedicinePeer-reviewed·Feb 22, 2025
- Personalizing computational models to construct medical digital twins
Adam Knapp, Daniel A. Cruz, … Reinhard Laubenbacher·Journal of The Royal Society InterfacePeer-reviewed·Jul 1, 2025