Optimal Multichannel Artifact Prediction and Removal for Brain Machine Interfaces and Neural Prosthetics
Mina Sadeghi Najafabadi, Longtu CheniD, Kelsey DuttaiD, Ashley Norris, Bin FengiD, Jan W. H. SchnuppiD, Nicole Roßkothen-KuhliD, Heather L. ReadiD, Monty A. Escabı́iD
Abstract
Neural implants that electrically stimulate neural tissue such as deep brain stimulators, cochlear implants (CI), and vagal nerve stimulators are becoming the routine treatment options for various diseases. Optimizing electrical stimulation paradigms requires closed-loop stimulation using simultaneous recordings of evoked neural activity in real time. Stimulus-evoked artifacts at the recording site are generally orders of magnitude larger than the neural signals, which challenge the interpretation of evoked neural activity. We developed a generalized artifact removal algorithm that can be applied in a variety of neural recording modalities. The procedure leverages known electrical stimulation currents to derive optimal filters that are used to predict and remove artifacts. We validated the procedure using paired recordings and electrical stimulation from sciatic nerve axons, high-rate bilateral CI stimulation, and concurrent multichannel stimulation in auditory midbrain and recordings in auditory cortex. We demonstrate a vast enhancement in the quality of recording even for high-throughput multi-site stimulation with typical improvements in the signal-to-noise ratio between 20-40 dB. The algorithm is efficient, can be scaled to arbitrary number of sites, and is applicable in range of recording modalities. It has numerous benefits over existing approaches and thus should be valuable for emerging neural recording and stimulation technologies.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 10
- FWCI
- 0.57
- Field percentile
- top 42%
- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- ERAASR: An algorithm for removing electrical stimulation artifacts from multielectrode array recordings
Daniel J. O’Shea, K.V. Shenoy·Journal of Neural EngineeringPeer-reviewed·Dec 21, 2017
- Neurostimulation Artifact Removal for Implantable Sensors Improves Signal Clarity and Decoding of Motor Volition
Eric J. Earley, Anton Berneving, … Max Ortiz-Catalan·Frontiers in Human NeurosciencePeer-reviewed·Oct 19, 2022
- Uncovering biomarkers during therapeutic neuromodulation with PARRM: Period-based Artifact Reconstruction and Removal Method
Evan M. Dastin-van Rijn, Nicole R. Provenza, … David A. Borton·Cell Reports MethodsPeer-reviewed·Jan 1, 2020
- Electrical Stimulus Artifact Cancellation and Neural Spike Detection on Large Multi-Electrode Arrays
Gonzalo E. Mena, Lauren E. Grosberg, … Liam Paninski·PLoS Computational BiologyPeer-reviewed·Nov 13, 2017
- Real-Time Spatiotemporal Filtering for Artifact-Free EEG during Electrical Neurostimulation
David Menrath, Joshua Pepe Woller, Alireza Gharabaghi·bioRxiv·Nov 6, 2024
- A Method for Electrical Stimulus Artifact Removal Exploiting Neural Refractoriness: Validation by Contrasting Cathodic and Anodic Stimulation
Arie Nakhmani, J. Block, … Harrison C. Walker·bioRxiv·Oct 6, 2024