CTFFIND5 provides improved insight into quality, tilt and thickness of TEM samples
Abstract
Images taken by transmission electron microscopes are usually affected by lens aberrations and image defocus, among other factors. These distortions can be modeled in reciprocal space using the contrast transfer function (CTF). Accurate estimation and correction of the CTF is essential for restoring the high-resolution signal in cryogenic electron microscopy (cryoEM). Previously, we described the implementation of algorithms for this task in the cisTEM software package (Grant et al., 2018). Here we show that taking sample characteristics, such as thickness and tilt, into account can improve CTF estimation. This is particularly important when imaging cellular samples, where measurement of sample thickness and geometry derived from accurate modeling of the Thon ring pattern helps judging the quality of the sample. This improved CTF estimation has been implemented in CTFFIND5, a new version of the cisTEM program CTFFIND. We evaluated the accuracy of these estimates using images of tilted aquaporin crystals and eukaryotic cells thinned by focused ion beam milling. We estimate that with micrographs of sufficient quality CTFFIND5 can measure sample tilt with an accuracy of 3{degrees} and sample thickness with an accuracy of 5 nm.
- assay: cryo-EM
- research focus: protein structure prediction
- approach: deep learning
- approach: statistical model
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- An approach for coherent periodogram averaging of tilt-series data for improved CTF estimation
Sagar Khavnekar, William Wan·bioRxiv·Oct 10, 2024
- Quinoa: Efficient and Robust CTF Estimation for CryoET Tilt Series
Thomas Frosio, Peijun Zhang·bioRxiv·Jul 16, 2026
- CTFFIND4: Fast and accurate defocus estimation from electron micrographs
Alexis Rohou, Nikolaus Grigorieff·bioRxiv·Aug 13, 2015
- goCTF: Geometrically optimized CTF determination for single-particle cryo-EM
M. Su·bioRxiv·Sep 25, 2018
- Dose-Efficient Cryo-Electron Microscopy for Thick Samples using Tilt-Corrected Scanning Transmission Electron Microscopy, Demonstrated on Cells and Single Particles
Yue Eric Yu, Katherine A. Spoth, … Lena Fitting Kourkoutis·Nature MethodsPeer-reviewed·Sep 23, 2025
- Gctf: real-time CTF determination and correction
Kai Zhang·bioRxiv·Jul 14, 2015