An approach for coherent periodogram averaging of tilt-series data for improved CTF estimation
Abstract
Cryo-electron microscopy (cryo-EM) has become an indispensable technique for determining three-dimensional structures of biological macromolecules. A critical aspect of achieving high-resolution cryo-EM reconstructions is accurately determining and correcting for the microscopes contrast transfer function (CTF). The CTF introduces defocus-dependent distortions during imaging; if not properly accounted for, the CTF can distort features in and limit the resolution of 3D reconstructions. For tilt-series data used in cryo-electron tomography (cryo-ET), CTF estimation becomes even more challenging due to the tilt of the specimen, which introduces a defocus gradient across the field of view, as well as the low dose and signal in individual tilt images. Here, we describe a simple algorithm to improve the accuracy of CTF estimation of tilted images by leveraging the tilt-series alignment parameters determined for tomographic reconstruction to explicitly account for the tilted specimen geometry. In brief, each tilt image is divided into patches, each of which are then stretched according to their defocus shift. These are then summed to provide a coherent power spectra at the tilt axis, which can then be used in standard CTF estimation algorithms. This uses all the data in each image to enhance the visibility of Thon rings, thereby improving high-resolution CTF estimation and subsequent enhancements in the resolution of subtomogram averages.
- Citations
- 4
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- CTFFIND5 provides improved insight into quality, tilt and thickness of TEM samples
J. Elferich, L. Kong, … N. Grigorieff·bioRxiv·Feb 26, 2024
- Quinoa: Efficient and Robust CTF Estimation for CryoET Tilt Series
Thomas Frosio, Peijun Zhang·bioRxiv·Jul 16, 2026
- Gradient based refinement of CryoET tilt series alignment improves tomogram contrast and structure resolution
Muyuan Chen·bioRxiv·Jan 19, 2026
- goCTF: Geometrically optimized CTF determination for single-particle cryo-EM
M. Su·bioRxiv·Sep 25, 2018
- Gctf: real-time CTF determination and correction
Kai Zhang·bioRxiv·Jul 14, 2015
- Improvements on marker-free images alignment for electron tomography
Carlos Óscar S. Sorzano, F.P. de Isidro-Gómez, … Cédric Messaoudi·Journal of Structural Biology XPeer-reviewed·Jan 1, 2020