bioRxivBiophysicsPreprint
Asymmetric spin echo multi-echo echo planar imaging (ASEME-EPI) sequence for pre-clinical high-field fMRI
Kyle A. JohnsoniD, Christopher P. PawelaiD, Andrew S. NenckaiD, Jason W. SidabrasiD
Abstract
In functional magnetic resonance imaging (fMRI) of the blood oxygen level-dependent (BOLD) contrast, gradient-recalled echo (GRE) acquisitions offer high sensitivity but suffer from susceptibility-induced signal loss and lack specificity to microvasculature. In contrast, spin echo (SE) acquisitions provide improved specificity at the cost of reduced sensitivity. This study introduces Asymmetric Spin Echo Multi-Echo Echo Planar Imaging (ASEME-EPI), a technique designed to combine the benefits of both GRE and SE for high-field preclinical fMRI. ASEME-EPI employs a spin echo readout followed by two asymmetric spin echo (ASE) GRE readouts, providing an initial T2-weighted SE image and subsequent T2*-weighted ASE images. A feasibility study for the technique was implemented on a 9.4 T pre-clinical MRI system and tested using a visual stimulation in northern tree shrews. Comparing ASEME-EPI with conventional GRE echo planar imaging (GRE-EPI) and SE echo planar imaging (SE-EPI) acquisitions, results showed that ASEME-EPI achieved BOLD contrast-to-noise ratio (CNR) comparable to GRE-EPI while offering improved specificity in activation maps. ASEME-EPI activation was more confined to the primary visual cortex (V1), unlike GRE-EPI which showed activation extending beyond anatomical boundaries. Additionally, ASEME-EPI demonstrated the ability to recover signal in areas of severe field inhomogeneity where GRE-EPI suffered from signal loss. The performance of ASEME-EPI is attributed to its multi-echo nature, allowing for SNR-optimized combination of echoes, effectively denoising the data. The inclusion of the initial SE also contributes to signal recovery in areas prone to susceptibility artifacts. This feasibility study demonstrates the potential of ASEME-EPI for high-field pre-clinical fMRI, offering a promising compromise between GRE sensitivity and SE specificity while addressing challenges of T2* decay at high field strengths.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Simultaneous pure T2 and varying T2'-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses
Fuyixue Wang, Zijing Dong, … Kawin Setsompop·NeuroImagePeer-reviewed·Oct 14, 2021
- Leveraging Multi-Echo EPI to Enhance BOLD Sensitivity in Task-based Olfactory fMRI
Ludwig Sichen Zhao, Clara U. Raithel, … Jay A. Gottfried·Imaging NeurosciencePeer-reviewed·Jan 1, 2024
- Advances in Spiral fMRI: A High-resolution Study with Single-shot Acquisition
Lars Kasper, Maria Engel, … Klaas P. Pruessmann·NeuroImagePeer-reviewed·Nov 17, 2021
- An optimized framework for simultaneous EEG-fMRI at 7T enabling safe, high-quality human brain imaging with millisecond temporal resolution and sub-millimeter spatial resolution
Cristina Sainz Martinez, Jonathan Wirsich, … João Jorge·bioRxiv·Aug 23, 2024
- Spatial specificity of the functional gradient echo and spin echo BOLD signal across cortical depth at 7 T
Daniel Haenelt, Robert Trampel, … Nikolaus Weiskopf·bioRxiv·Jul 28, 2025
- Hi-Fi fMRI: High-resolution, fast-sampled and sub-second whole-brain functional MRI at 3T in humans
Benedetta Franceschiello, Simone Rumac, … Eleonora Fornari·bioRxiv·May 13, 2023