OpticaNeurosciencePeer-reviewed journal article
Non-inertial scan angle multiplier for expanded fields-of-view
Che‐Hang YuiD, Yiyi YuiD, Joseph S. CanzanoiD, Yaolin Fei, Filip TomáškaiD, Spencer L. SmithiD
Abstract
In many laser scan engines, mechanical inertia imposes a tradeoff between mirror diameter (mass) and scan speed (cycle time) and/or scan angle amplitude. Ultimately, this limits the field-of-view and/or scan speed in multiphoton and confocal imaging, laser-based manufacturing, and other applications. To push parameters past this inertia limit, we present a non-inertial (stationary) add-on unit that doubles the scan angle amplitude while preserving both the beam size and cycle time, thus doubling the etendue (optical invariant) and overall system throughput. We demonstrate its use in two-photon calcium imaging of neural activity in living mice. We also adapt the approach to present a phase doubling unit that doubles the maximum range of phase modulators. Finally, we describe further variants including generalizing the approach to Nx scan angle multiplication (N = 2, 3, 4, ...) with diffraction limited performance across a wide scan angle range and over a broad wavelength bandwidth. These non-inertial scan angle multipliers (called Nisam2x, 3x, ...) can expand the capabilities of a range of technologies including imaging, adaptive optics, sensing, marking, and manufacturing.
- Citations
- 5
- FWCI
- 6.45
- Field percentile
- top 4%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Fiber optical parametric amplification of low-photon-flux microscopy signals
Jeffrey Demas, L. Tan, Siddharth Ramachandran·bioRxiv·Mar 30, 2026
- Two-photon microscopy at >500 volumes/second
Y.-H. Tsai, C.-W. Liu, … S.-W. Chu·bioRxiv·Oct 21, 2020
- Scan field rotation with a K-mirror for fast two-photon imaging along curved planes
Shinjini Ghosh, Luca Godenzini, … Peter Rupprecht·bioRxiv·Oct 13, 2026
- Converting lateral scanning into axial focusing to speed up 3D microscopy
T. Chakraborty, B.-J. Chang, … R. P. Fiolka·bioRxiv·Mar 6, 2020
- Transient Room Lighting for Ambient Light Multiphoton Microscopy
A. Velten, A. J. Uselmann, … K. W. Eliceiri·bioRxiv·Aug 4, 2020
- Fast and artifact-free excitation multiplexing using synchronized image scanning
E. Bruggeman, R. Van den Eynde, … P. Dedecker·bioRxiv·Feb 7, 2023