American Journal of Respiratory Cell and Molecular BiologyBioengineeringPeer-reviewed journal article
A novel precision-cut lung slice stretch model using removable inflation materials
Cassidy Potter, Jeannie HaakiD, D. Dean, Andrew M. DylagiD, Jared A. MerenessiD
Abstract
Stretch is an important biomechanical stimulus facilitating tissue development in the respiratory system by programming the epithelium, endothelium, and extracellular matrix (ECM). Lung tissue undergoes stretch induced lung differentiation under normal prenatal and postnatal development. Furthermore, supraphysiological and aberrant stretch responses are known mechanisms of acute lung injury and ECM disruption. Current in vitro human tissue cyclic mechanical stretch (CMS) models suffer from significant, well-recognized disadvantages and are poorly validated in vivo for longer-term study. In vitro precision-cut lung slice (PCLS) models are commonly used to study the complex structural arrangement and cellular interactions of human tissue, as well as various lung diseases, including BPD.3 PCLS maintain lung tissue architecture and the variety of cell types present in the lung, allowing for a more realistic imitation of the lung microenvironment.3 Existing agarose-inflated PCLS models are hindered by retention of agarose media in the tissue, affecting material properties and complicating stretch studies. Our novel PCLS approach utilizes several technical innovations including a removable hydrogel for inflation and uses supportive poly(ethylene glycol) (PEG) hydrogels enable improved viability and phenotype retention during cyclic mechanical stretch (CMS). This platform will induce PCLS CMS for biochemical assays (e.g. transcriptomics, proteomics) after exposure.
- Citations
- 0
- FWCI
- 0.00
- Field percentile
- 6th percentile
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Reduced biomechanical models for precision-cut lung-slice stretching experiments
Hannah J Pybus, Lowell T Edgar, … Bindi S Brook·bioRxiv·Jul 9, 2020
- 3D printed lung on a chip device with a stretchable nanofibrous membrane for modeling ventilator induced lung injury
S. Tas, E. Rehnberg, … D. E. Wagner·bioRxiv·Jul 2, 2021
- Hydrogel-Embedded Precision-Cut Lung Slices Recapitulate Fibrotic Gene Expression and Enable Therapeutic Response Evaluation
Alicia E. Tanneberger, Rachel Blomberg, … Chelsea M. Magin·bioRxiv·Mar 27, 2026
- Hydrogel-embedded precision-cut lung slices support ex vivo culture of in vivo-induced premalignant lung lesions
Caroline Hauer, Rachel Blomberg, … Meredith A. Tennis·Physiological ReportsPeer-reviewed·Jul 1, 2025
- Single-cell transcriptomic assessment of cellular phenotype stability in human precision-cut lung slices
N. I. Winters, C. J. Taylor, … J. A. Kropski·bioRxiv·Aug 19, 2021
- Second-generation lung-on-a-chip array with a stretchable biological membrane
P. Zamprogno, S. Wuthrich, … O. T. Guenat·bioRxiv·Apr 18, 2019