NanoAmpli-Seq: A workflow for amplicon sequencing for mixed microbial communities on the nanopore sequencing platform
Abstract
BackgroundAmplicon sequencing on Illumina sequencing platforms leverages their deep sequencing and multiplexing capacity, but is limited in genetic resolution due to short read lengths. While Oxford Nanopore or Pacific Biosciences platforms overcome this limitation, their application has been limited due to higher error rates or smaller data output.\n\nResultsIn this study, we introduce an amplicon sequencing workflow, i.e., NanoAmpli-Seq, that builds on Intramolecular-ligated Nanopore Consensus Sequencing (INC-Seq) approach and demonstrate its application for full-length 16S rRNA gene sequencing. NanoAmpli-Seq includes vital improvements to the aforementioned protocol that reduces sample-processing time while significantly improving sequence accuracy. The developed protocol includes chopSeq software for fragmentation and read orientation correction of INC-Seq consensus reads while nanoClust algorithm was designed for read partitioning-based de novo clustering and within cluster consensus calling to obtain full-length 16S rRNA gene sequences.\n\nConclusionsNanoAmpli-Seq accurately estimates the diversity of tested mock communities with average sequence accuracy of 99.5% for 2D and 1D2 sequencing on the nanopore sequencing platform. Nearly all residual errors in NanoAmpli-Seq sequences originate from deletions in homopolymer regions, indicating that homopolymer aware basecalling or error correction may allow for sequencing accuracy comparable to short-read sequencing platforms.
02 /Specification & Classification
Click any tag to browse matching papers- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- High-accuracy meets high-throughput for microbiome profiling with near full-length 16S rRNA amplicon sequencing on the Nanopore platform
- Nanopore sequencing reaches amplicon sequence variant (ASV) resolution
Marie Riisgaard-Jensen, Stefania Andrea Rosso Villanelo, … Morten Simonsen Dueholm·bioRxiv·Feb 28, 2026
- Species-level resolution of 16S rRNA gene amplicons sequenced through MinIONTM portable nanopore sequencer
Alfonso Benitez-Paez, Kevin Portune, Yolanda Sanz·bioRxiv·Jan 11, 2016
- INC-Seq: Accurate single molecule reads using nanopore sequencing
Chenhao Li, Kern Rei Chng, … Niranjan Nagarajan·GigasciencePeer-reviewed·Aug 2, 2016
- A sample-to-report solution for taxonomic identification of cultured bacteria in the clinical setting based on nanopore sequencing
S. M. Neuenschwander, M. A. Terrazos Miani, … A. Ramette·Journal of Clinical MicrobiologyPeer-reviewed·May 26, 2020
- Ultra-High Multiplexing Enables Near-Full-Length 16S rRNA Gene Amplicon Sequencing of Over 1,200 Gut Microbiome Samples on a Single Nanopore Flow Cell
Charlie H. McPhillips, Eoghan Thomas Reilly, … Łukasz Krych·bioRxiv·Aug 29, 2026