Advanced Manufacturing of Coil-Reinforced Multilayer Vascular Grafts to Optimize Biomechanical Performance

Andrew William Taylor-RobinsoniD, David D. JiangiD, Abbey NkansahiD, Juan S. Herrera DuraniD, Jonathan Leung, Madeline LaudeiD, John Craig, Leopold GuoiD, Lucas H. TimminsiD, Elizabeth Cosgriff‐HernandeziD

PDFDOIPreprint

Abstract

Small diameter vascular grafts require a complex balance of biomechanical properties to achieve target burst pressure, arterial compliance-matching, and kink resistance to prevent failure. Iterative design of our multilayer vascular was previously used to achieve high compliance while retaining the requisite burst pressure and suture retention strength for clinical use. To impart kink resistance, a custom 3D solution printer was used to add a polymeric coil to the electrospun polyurethane graft to support the graft during bending. The addition of this reinforcing coil increased kink resistance but reduced compliance. A matrix of grafts were fabricated and tested to establish key structure-property relationships between coil parameters (spacing, diameter, modulus) and biomechanical properties (compliance, kink radius). A successful graft design was identified with a compliance similar to saphenous vein grafts (4.1 {+/-} 0.4 %/mmHgx10-2) while maintaining comparable kink resistance to grafts used currently in the clinic. To explore graft combinations that could increase graft compliance to match arterial values while retaining this kink resistance, we utilized finite element (FE) models of compliance and kink radius that simulated experimental testing. The FE-predicted graft compliance agreed well with experimental values. Although the kink model over-predicted the experimental kink radius values, key trends between graft parameters and kink resistance were reproduced. As an initial proof-of-concept, the validated models were then utilized to parse through a targeted graft design space. Although this initial parameter range tested did not yield a graft that improved upon the previous balance of graft properties, this combination of advanced manufacturing and computational framework paves the way for future model-driven design to further optimize graft performance. TOC O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=97 SRC="FIGDIR/small/633374v1_ufig1.gif" ALT="Figure 1"> View larger version (45K): org.highwire.dtl.DTLVardef@faca56org.highwire.dtl.DTLVardef@f9dccforg.highwire.dtl.DTLVardef@fbb5corg.highwire.dtl.DTLVardef@d5c021_HPS_FORMAT_FIGEXP M_FIG C_FIG

Citations
7
FWCI
1.46
Field percentile
top 22%

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.

Similarity Map
SelectedSame fieldCross-field
THISJiang '24Zermeno '26Rovas '23Nkansah '26Robinson '23Krynauw '20
79% semantic matchBioengineering
David D. Jiang, Andrew J. Robinson, Abbey Nkansah+6 more·Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials·Dec 4, 2024· 4 citations