Heparinized Elastomeric Nanofibrillar Grafts: A Novel Approach for Mechanically Tunable, Cell-Supportive, and Thromboresistant Vascular Substitutes
Elizabeth C. ZermenoiD, John M. Kapitan, Alexander D Sandquist, Amanda Reke, Apurbo Kumar Paul, Jason MacTaggartiD, Stephen A. MoriniD, Kaspars MaleckisiD
Abstract
The clinical success of vascular grafts relies on three main prerequisites: artery-tuned mechanics, cell-supportive microstructure, and a thromboresistant interface. Most current solutions address only a subset of this triad and equate mechanical matching with compliance alone, which can lead to disturbed hemodynamics, maladaptive mechanobiology, and adverse graft-host biochemical interactions that frequently culminate in clinical complications and graft failure. This study presents polyurethane-based heparin-functionalized elastomeric nanofibrillar grafts (H-ENGs) that integrate all three prerequisites while allowing multi-parameter mechanical mimicry. To address the principal failure mode of early thrombosis, a small fraction of polyethyleneimine (PEI) is added to the ENG electrospinning solution to form P-ENGs, enabling one-step covalent heparin conjugation to form H-ENGs. The decoupled design of the ENG platform preserves the biomimetic microstructure and mechanics following PEI incorporation and heparinization, enabling adaptable, indication-specific optimization. In vitro, H-ENGs exhibit good cytocompatibility with minimal hemolysis, platelet adhesion, and whole blood clotting. Pilot porcine abdominal aorta interposition studies demonstrate feasibility: H-ENGs exhibit favorable surgical handling, intact suture-line integrity, and anastomotic hemostasis under dynamic flow, and retain artery-tuned mechanics and surface heparin at two weeks. While further testing is warranted, these results indicate that H-ENGs satisfy the three prerequisites for vascular graft clinical success. Graphical Abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=68 SRC="FIGDIR/small/701857v1_ufig1.gif" ALT="Figure 1"> View larger version (23K): org.highwire.dtl.DTLVardef@1e09f2aorg.highwire.dtl.DTLVardef@1f1b5baorg.highwire.dtl.DTLVardef@1d1fba6org.highwire.dtl.DTLVardef@e066ca_HPS_FORMAT_FIGEXP M_FIG C_FIG
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Off-the-Shelf Multilayer Vascular Grafts with Damage-Resistant Hydrogel Coatings Incorporating Integrin Targeting
Abbey Nkansah, Ashauntee Fairley, … Elizabeth Cosgriff‐Hernandez·bioRxiv·Jul 29, 2026
- Hierarchically Vascularized and Implantable Tissue Constructs created through Angiogenesis from Tissue-Engineered Vascular Grafts
Hazem Alkazemi, Geraldine M. Mitchell, … Andrea J. O’Connor·Acta BiomaterialiaPeer-reviewed·Oct 3, 2024
- A Micro-Patterned, hiPSC-Derived Vascular Graft with Enhanced Endothelialization via Shear Redistribution
Jagoda Litowczenko, Yasmin Richter, … Ángel Raya·bioRxiv·Apr 15, 2026
- In vivo recellularization of xenogeneic vascular grafts decellularized with high hydrostatic pressure method in a porcine carotid arterial interpose model
S. Kurokawa, Y. Hashimoto, … H. Masumoto·bioRxiv·May 29, 2020
- Advanced Manufacturing of Coil-Reinforced Multilayer Vascular Grafts to Optimize Biomechanical Performance
Andrew William Taylor-Robinson, David D. Jiang, … Elizabeth Cosgriff‐Hernandez·Acta BiomaterialiaPeer-reviewed·Apr 9, 2025
- Evaluation of Densified Collagen Tubes as an Interposition Graft in Abdominal Aorta
Alexander W. Justin, Md. Abdullah Al Fahad, … Athina E. Markaki·bioRxiv·Oct 9, 2026