Axon morphology is modulated by the local environment and impacts the non-invasive investigation of its structure-function relationship
Mariam AnderssoniD, Hans Martin KjeriD, Jonathan Rafael‐PatiñoiD, Alexandra PacureanuiD, Bente PakkenbergiD, Jean‐Philippe ThiraniD, Maurice PtitoiD, Martin BechiD, Anders Bjorholm DahliD, Vedrana Andersen DahliD, Tim B. DyrbyiD
Abstract
Axonal conduction velocity, which ensures efficient function of the brain network, is related to axon diameter. Non-invasive, in vivo axon diameter estimates can be made with diffusion magnetic resonance imaging, but the technique requires 3D validation. Here, high resolution, 3D synchrotron X-ray Nano-Holotomography images of white matter samples from the corpus callosum of a monkey brain reveal that blood vessels, cells and vacuoles affect axonal diameter and trajectory. Within single axons, we find that the variance in diameter and conduction velocity correlates with the mean diameter, contesting the value of precise diameter determination in larger axons. These complex 3D axon morphologies drive previously reported 2D trends in axon diameter and g-ratio. Furthermore, we find that these morphologies bias the estimates of axon diameter with diffusion magnetic resonance imaging and, ultimately, impact the investigation and formulation of the axon structure-function relationship.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 95
- FWCI
- 5.60
- Field percentile
- top 3%
- Organism
- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Mapping axon diameters and conduction velocity in the rat brain - different methods tell different stories of the structure-function relationship
Christian Stald Skoven, Mariam Andersson, … Tim B. Dyrby·Imaging NeurosciencePeer-reviewed·Jan 1, 2025
- Does powder averaging remove dispersion bias in diffusion MRI diameter estimates within real 3D axonal architectures?
Mariam Andersson, Marco Pizzolato, … Tim B. Dyrby·NeuroImagePeer-reviewed·Nov 9, 2021
- 3D Histology Validates 2D Histology for Axon Radius Distributions and Conduction Velocities
Laurin Mordhorst, Nikolaus Weiskopf, … Siawoosh Mohammadi·Communications BiologyPeer-reviewed·Oct 27, 2026
- The influence of axonal beading and undulation on axonal diameter mapping
Hong‐Hsi Lee, Qiyuan Tian, … Susie Y. Huang·bioRxiv·Apr 19, 2023
- Axon Diameter Measurements using Diffusion MRI are Infeasible
M. Paquette, C. Eichner, … A. Anwander·bioRxiv·Oct 1, 2020
- Mapping axon conduction delays in vivo from microstructural MRI
Mark Drakesmith, Robbert Harms, … Derek Kenton Jones·NeuroImagePeer-reviewed·Sep 19, 2019