Scientific ReportsPhysiologyPeer-reviewed journal article
Does PERM1 Regulate Systolic Cardiac Function? A Game of Numbers.
Alexey V. ZaitseviD, Karthi SreedeviiD, Brianna Goode, Junco S. WarreniD
Abstract
We and others demonstrated that PERM1 is a positive regulator of mitochondrial bioenergetics in the heart. However, discrepant results have emerged with regard to whether PERM1 loss-of-function affect cardiac contractility. In order to exclude the possibility that the reported negative results can be due to insufficient power of statistical test, we conducted a more robust echocardiography (Echo) analysis by increasing the sample size. We used Perm1-KO and their respective wildtype (WT) littermates, which were destined to tissue harvest. This yielded 84 WT mice and 88 Perm1-KO mice. We analyzed Echo-derived parameters of left ventricular (LV) systolic function. At the end of the study, ejection fraction (EF) was 65.43 {+/-} 7.13 in WT vs. 53.98 {+/-} 8.80 in Perm1-KO yielding p < 0.00000000000000004. Other parameters which reached statistically significant difference between WT and Perm1-KO (at p < 0.05) included LV fractional shortening (FS), LV diastolic and systolic diameters, LV anterior and posterior systolic wall thickness, LV posterior wall systolic thickening, stroke volume, and cardiac output (CO). Retrospectively, a p value < 0.05 was consistently achieved in assessment of EF only after average N per group reached 13. Larger minimal N per group were required for other parameters. Of interest, in both groups there were no correlation between EF% and CO. At the same time, in both groups EF strongly inversely correlated with LV diastolic diameter. This led us to a speculation that low EF may be in part compensated by an increased LV circumference, for the purpose of maintaining invariant CO. Indeed, the intergroup difference in CO (6%) was much smaller than the intergroup difference in EF (18%). We conclude that PERM1 does regulate cardiac mechanics. Changes caused by constitutive Perm1-KO can be conceptualized as reduced contractility partially compensated by increased LV circumference. This study underscores the importance of sufficiently large sample size for detecting significant differences in Echo data.
- Citations
- 0
- FWCI
- 0.00
- Field percentile
- 7th percentile
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Simultaneous assessment of mechanical and electrical function in Langendorff-perfused ex-vivo mouse heart
J. Louradour, R. Ottersberg, … S. Longnus·bioRxiv·Sep 15, 2023
- PERM1 Gene Delivery via AAV Prevents Heart Failure in a Mouse Model of Pressure Overload
Karthi Sreedevi, Ryan N. Montalvo, … Junco S. Warren·bioRxiv·Sep 29, 2025
- Cardiac pericytes are necessary for coronary vasculature integrity and cardiomyocyte differentiation
L. Cornuault, F.-X. Herion, … M.-A. Renault·bioRxiv·Aug 29, 2022
- Cardiomyocyte Perm1 sustains cardiac bioenergetic reserve and exercise capacity
Shizuko Tachibana, Tina Le, … Yoshitake Cho·bioRxiv·Oct 10, 2026
- Peroxisome protein import deficiency causes heart failure in mouse and human
Julia Hofhuis, Malte Tiburcy, … Sven Thoms·bioRxiv·Oct 13, 2025
- Sympathetic activation and the force-frequency relationship in heart failure with reduced ejection fraction
Sam Straw, Ankit Gupta, … John Gierula·bioRxiv·Sep 1, 2026