Simultaneous assessment of mechanical and electrical function in Langendorff-perfused ex-vivo mouse heart
J. Louradour, R. Ottersberg, A. Segiser, A. Olejnik, B. Martinez-Salazar, M. Siegrist, M. Egle, M. Barbieri, S. Nimani, N. Alerni, Y. Döring, K. E. Odening, S. Longnus
Abstract
BackgroundThe Langendorff-perfused ex-vivo isolated heart model has been extensively used to study cardiac function for many years. However, electrical and mechanical function are often studied separately - despite growing proof of a complex electro-mechanical interaction in cardiac physiology and pathology. Therefore, we developed an isolated mouse heart perfusion system that allows simultaneous recording of electrical and mechanical function. MethodsIsolated mouse hearts were mounted on a Langendorff setup and electrical function was assessed via a pseudo-ECG and an octapolar catheter inserted in the right atrium and ventricle. Mechanical function was simultaneously assessed via a balloon inserted into the left ventricle coupled with pressure determination. Hearts were then submitted to an ischemia-reperfusion protocol. ResultsAt baseline, heart rate, PR and QT intervals, intra-atrial and intra-ventricular conduction times, as well as ventricular effective refractory period, could be measured as parameters of cardiac electrical function. Left ventricular developed pressure (DP), left ventricular work (DP-heart rate product) and maximal velocities of contraction and relaxation were used to assess cardiac mechanical function. Cardiac arrhythmias were observed with episodes of bigeminy during which DP was significantly increased compared to that of sinus rhythm episodes. In addition, the extrasystole-triggered contraction was only 50% of that of sinus rhythm, recapitulating the "pulse deficit" phenomenon observed in bigeminy patients. After ischemia, the mechanical function significantly decreased and slowly recovered during reperfusion while most of the electrical parameters remained unchanged. Finally, the same electro-mechanical interaction during episodes of bigeminy at baseline was observed during reperfusion. ConclusionOur modified Langendorff setup allows simultaneous recording of electrical and mechanical function on a beat-to-beat scale and can be used to study electro-mechanical interaction in isolated mouse hearts.
02 /Specification & Classification
Click any tag to browse matching papers- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Revisiting Mouse Cardiac Myocyte Isolation: A Simplified Langendorff-based Method
Mie Larsen, Morten Bækgaard Thomsen, Tamzin Zawadzki·bioRxiv·Apr 17, 2026
- Does PERM1 Regulate Systolic Cardiac Function? A Game of Numbers.
Alexey V. Zaitsev, Karthi Sreedevi, … Junco S. Warren·Scientific ReportsPeer-reviewed·Feb 7, 2026
- Mechanical stimulation of endocardial Purkinje fibres can trigger ventricular arrhythmias
E. c, R. D. Walton, … M.-L. Ward·bioRxiv·Aug 10, 2020
- Disturbed repolarisation-relaxation coupling during acute ischaemia permits systolic mechano-arrhythmogenesis.
Breanne Ashleigh Cameron, Peter Baumeister, … Thomas Alexander Quinn·Circulation ResearchPeer-reviewed·Jun 2, 2025
- A novel minimally invasive and reproducible large animal ischaemia-reperfusion-infarction model: methodology and model validation
C. Pius, B. Niort, … A. Trafford·bioRxiv·Mar 2, 2023
- Integrated multi-modal data analysis for computational modeling of healthy and location-dependent myocardial infarction conditions in porcine hearts
Ricardo M. Rosales, Ming Wu, … Esther Pueyo·PLoS Computational BiologyPeer-reviewed·Mar 16, 2026