The Value of Zero-filling in In Vivo MRS
Saipavitra Murali‐ManohariD, Georg OeltzschneriD, Peter B. BarkeriD, Richard A.E. EddeniD
Abstract
Two opinions currently exist on the role of zero-filling in data processing for in vivo MRS: that it results in a purely cosmetic interpolation; or that it confers a benefit. Most commonly, in vivo MRS data are acquired as complex time-domain half-echoes, that are Fourier transformed to the give a real spectrum that is modeled for quantification. In this manuscript, we highlight that performing zero-filling draws the independent information from the imaginary part of the spectrum into the real spectrum, improving modeling accuracy. In order to demonstrate this, 10,000 time-domain datasets were simulated as decaying exponentials and noise was added. Data were then Fourier transformed with no-zero filling, 2x, 4x and 8x zero-filling. All spectra were then modeled using a simple single-Lorentzian frequency-domain model. It was demonstrated that 2x zero-filling results in a [~]{surd}2 benefit in modeling accuracy, compared to no zero-filling. There was no additional advantage for further zero-filling.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 3
- FWCI
- 0.43
- Field percentile
- top 46%
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Towards harmonized spectral quantification in MRSI: Comparative analysis of Backward-Linear-Predicted and original 1H-FID-MRSI dephased data
Alessio Siviglia, Brayan Alves, … Bernard Lanz·Magnetic Resonance Materials in Physics Biology and MedicinePeer-reviewed·May 14, 2026
- MRS-Sim: Open-Source Framework for Simulating Realistic In Vivo-like MR Spectroscopy Data
John LaMaster, Georg Oeltzschner, Yan Li·NMR in BiomedicinePeer-reviewed·Sep 16, 2025
- FSL-MRS: An end-to-end spectroscopy analysis package
William T. Clarke, Charlotte Jane Stagg, Saâd Jbabdi·Magnetic Resonance in MedicinePeer-reviewed·Dec 6, 2020
- MR Spectroscopy without Water Suppression using the Gradient Impulse Response Function
James B Bacon, Peter Jezzard, William T Clarke·Magnetic Resonance in MedicinePeer-reviewed·May 5, 2026
- Uncertainty in denoising of MRSI using low-rank methods
William T. Clarke, Mark Chiew·Magnetic Resonance in MedicinePeer-reviewed·Sep 21, 2021
- Adaptive Baseline Fitting for 1H MR Spectroscopy Analysis
M. Wilson·bioRxiv·Feb 17, 2020