Neural network emulation of the human ventricular cardiomyocyte action potential: a tool for more efficient computation in pharmacological studies
T. Grandits, C. M. Augustin, G. Haase, N. Jost, G. R. Mirams, S. A. Niederer, G. Plank, A. Varro, L. Virag, A. Jung
Abstract
AbstractComputer models of the human ventricular cardiomyocyte action potential (AP) have reached a level of detail and maturity that has led to an increasing number of applications in the pharmaceutical sector. However, interfacing the models with experimental data can become a significant computational burden. To mitigate the computational burden, the present study introduces a neural network (NN) that emulates the AP for given maximum conductances of selected ion channels, pumps, and exchangers. Its applicability in pharmacological studies was tested on synthetic and experimental data. The NN emulator potentially enables massive speed-ups compared to regular simulations and the forward problem (find drugged AP for pharmacological parameters defined as scaling factors of control maximum conductances) on synthetic data could be solved with average root-mean-square errors (RMSE) of 0.47 mV in normal APs and of 14.5 mV in abnormal APs exhibiting early afterdepolarizations (72.5% of the emulated APs were alining with the abnormality, and the substantial majority of the remaining APs demonstrated pronounced proximity). This demonstrates not only very fast and mostly very accurate AP emulations but also the capability of accounting for discontinuities, a major advantage over existing emulation strategies. Furthermore, the inverse problem (find pharmacological parameters for control and drugged APs through optimization) on synthetic data could be solved with high accuracy shown by a maximum RMSE of 0.21 in the estimated pharmacological parameters. However, notable mismatches were observed between pharmacological parameters estimated from experimental data and distributions obtained from the Comprehensive in vitro Proarrhythmia Assay initiative. This reveals larger inaccuracies which can be attributed particularly to the fact that small tissue preparations were studied while the emulator was trained on single cardiomyocyte data. Overall, our study highlights the potential of NN emulators as powerful tool for an increased efficiency in future quantitative systems pharmacology studies.
02 /Specification & Classification
Click any tag to browse matching papers- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Personalization of mathematical models of human atrial action potential
A. V. Pikunov, R. A. Syunyaev, … I. R. Efimov·bioRxiv·Jun 29, 2020
- Genetic algorithm-based personalized models of human cardiac action potential
D. N. Smirnov, R. A. Syunyaev, … I. R. Efimov·bioRxiv·Jul 23, 2019
- Assessing drug safety by identifying the axis of arrhythmia in cardiomyocyte electrophysiology
S. Heitmann, J. I. Vandenberg, A. P. Hill·bioRxiv·Apr 19, 2023
- Computational Model for Simulating Drug-Induced Arrhythmia Sensitivity of Human iPSC-derived Cardiomyocytes
Xin Gao, Yue Yin, … Tetsuro Wakatsuki·bioRxiv·Dec 18, 2017
- Sensitivity and uncertainty analysis of two human atrial cardiac cell models using Gaussian process emulators
S. Coveney, R. H. Clayton·Frontiers in PhysiologyPeer-reviewed·Apr 23, 2020
- Four ways to fit an ion channel model
M. Clerx, K. A. Beattie, … G. R. Mirams·bioRxiv·Apr 16, 2019