bioRxivBiochemistry
Limits for resolving tandem mass tag reporter ions with identical integer mass using phase constrained spectrum deconvolution
C. D. Kelstrup, K. Aizikov, T. S. Batth, A. Kreutzman, D. Grinfeld, O. Lange, D. Mourad, A. Makarov, J. V. Olsen
Abstract
A popular method for peptide quantification relies on isobaric labeling such as tandem mass tags (TMT) which enables multiplexed proteome analyses. Quantification is achieved by reporter ions generated by fragmentation in a tandem mass spectrometer. However, with higher degrees of multiplexing, the smaller mass differences between the reporter ions increase the mass resolving power requirements. This contrasts with faster peptide sequencing capabilities enabled by lowered mass resolution on Orbitrap instruments. It is therefore important to determine the mass resolution limits for highly multiplexed quantification when maximizing proteome depth. Here we defined the lower boundaries for resolving TMT reporter ions with 0.0063 Da mass differences using an ultra-high-field Orbitrap mass spectrometer. We found the optimal method depends on the relative ratio between closely spaced reporter ions and that 64 ms transient acquisition time provided sufficient resolving power for separating TMT reporter ions with absolute ratio changes up to 16-fold. Furthermore, a 32 ms transient processed with phase-constrained spectrum deconvolution provides >50% more identifications with >99% quantified, but with a slight loss in quantification precision and accuracy. These findings should guide decisions on what Orbitrap resolution settings to use in future proteomics experiments relying on TMT reporter ion quantification with identical integer masses.
- assay: proteomics
- research focus: variant calling
- research focus: differential expression
- research focus: protein folding & dynamics
- approach: statistical model
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- High Resolution Multi-Pass Astral Analyzer Quantification Enables Highly Multiplexed 35-Plex Tandem Mass Tag Proteomics
Hamish Stewart, Steven R. Shuken, … Steven P. Gygi·bioRxiv·Feb 26, 2026
- Super-resolution mass spectrometry enables rapid, accurate, and highly-multiplexed proteomics at the MS2-level
Anton N. Kozhinov, Alex N. T. Johnson, … Yury O. Tsybin·Analytical ChemistryPeer-reviewed·Feb 7, 2023
- Accurate, Sensitive, and Precise Multiplexed Proteomics using the Complement Reporter Ion Cluster
Matthew Sonnett, Eyan Yeung, Martin Wühr·Analytical ChemistryPeer-reviewed·Mar 9, 2018
- Prior Signal Acquisition Software Versions for Orbitrap Underestimate Low Isobaric Mass Tag Intensities, Without Detriment to Differential Abundance Experiments
Tom S. Smith, Anna Andrejeva, … Kathryn Susan Lilley·ACS Measurement Science AuPeer-reviewed·Mar 9, 2022
- TMTPro Complementary Ion Quantification Increases Plexing and Sensitivity for Accurate Multiplexed Proteomics at the MS2 Level
Alex N. T. Johnson, Michael Stadlmeier, Martin Wühr·Journal of Proteome ResearchPeer-reviewed·Apr 30, 2021
- Direct Measurement of Synchronous Precursor Selection (SPS) Accuracy in Public Proteomics Datasets
Conor Jenkins, Aimee Rinas, Benjamin C. Orsburn·bioRxiv·May 24, 2019