bioRxivBioinformaticsPreprint
Direct Measurement of Synchronous Precursor Selection (SPS) Accuracy in Public Proteomics Datasets
Abstract
Reporter ion quantification techniques utilizing reagents such as TMT and iTRAQ allow proteomics studies to multiplex up to 11 different samples within a single LC-MS/MS experimental run. In these experiments, peptides derived from different samples are labeled with chemical tags possessing identical mass but differing distributions of heavy isotopes through their structure. Peptides from all samples may then be physically combined prior to LC-MS/MS. Relative quantification of the peptides from each sample is obtained from the liberation of low mass reporter ions alone, as these are the only discernible factor between peptides in the entire LC-MS/MS workflow. When coeluting ions of similar mass to charge ratios are fragmented along with the ions of interest, it is not possible to determine the source of the reporter fragments and quantification is skewed, most often resulting in ratio suppression. One technique for combatting ratio suppression is the selection of MS2 fragment ions that are likely to retain the intact mass tag region by synchronous precursor selection (SPS) and the liberation of the reporter ions from this combination of ions in MS/MS/MS (MS3). In this study we utilize a new post processing tool that can directly assess the accuracy of the SPS system for picking ions for quantification that are truly derived from the peptide of interest. We then apply this tool to the re-analysis of 3 public proteomics datasets. Directly assessing SPS accuracy allows a new measurement of confidence in the quantification values obtained from these reporter ion quantification experiments.\n\nAbstract Graphic\n\nO_FIG O_LINKSMALLFIG WIDTH=185 HEIGHT=200 SRC=\"FIGDIR/small/647917v1_ufig1.gif\" ALT=\"Figure 1\">\nView larger version (26K):\norg.highwire.dtl.DTLVardef@1186337org.highwire.dtl.DTLVardef@19c0daorg.highwire.dtl.DTLVardef@c44d31org.highwire.dtl.DTLVardef@1a7d597_HPS_FORMAT_FIGEXP M_FIG C_FIG
- Citations
- 1
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Prior Signal Acquisition Software Versions for Orbitrap Underestimate Low Isobaric Mass Tag Intensities, Without Detriment to Differential Abundance Experiments
Tom S. Smith, Anna Andrejeva, … Kathryn Susan Lilley·ACS Measurement Science AuPeer-reviewed·Mar 9, 2022
- Limits for resolving tandem mass tag reporter ions with identical integer mass using phase constrained spectrum deconvolution
C. D. Kelstrup, K. Aizikov, … J. V. Olsen·bioRxiv·May 28, 2018
- TMTPro Complementary Ion Quantification Increases Plexing and Sensitivity for Accurate Multiplexed Proteomics at the MS2 Level
Alex N. T. Johnson, Michael Stadlmeier, Martin Wühr·Journal of Proteome ResearchPeer-reviewed·Apr 30, 2021
- Accurate, Sensitive, and Precise Multiplexed Proteomics using the Complement Reporter Ion Cluster
Matthew Sonnett, Eyan Yeung, Martin Wühr·Analytical ChemistryPeer-reviewed·Mar 9, 2018
- Improved LC-MS chromatographic alignment increases the accuracy of label-free quantitative proteomics: Comparison of spectral counting versus ion intensity-based proteomic quantification strategies.
Daniel Ng, Jonathan D. Humphries, … Martin James Humphries·bioRxiv·Feb 24, 2017
- Strategies based on sum of peak intensities may better reflect protein expression than peak area integration in iTRAQ protein expression measurement by LC-MS/MS using a TripleTOF 5600+ platform
B. Burat, J. Gonzalez, … M. Essig·bioRxiv·Mar 13, 2019