Sign in
NeuroscienceeLife
Peer-reviewed journal article

Ultrastructural comparison of dendritic spine morphology preserved with cryo and chemical fixation

Hiromi TamadaiD, Jerome Blanc, Natalya KorogodiD, Carl C.H. PeterseniD, Graham William KnottiD

Abstract

Previously we showed that cryo fixation of brain tissue gave a truer representation of brain ultrastructure in comparison with a standard chemical fixation method (Korogod et al 2005). Extracellular space matched physiological measurements, there were larger numbers of docked vesicles and less glial coverage of synapses and blood capillaries. Here, using the same preservation approaches we compared the morphology of dendritic spines. We show that the length of the spine and the volume of its head is unchanged, however, the spine neck width is thinner by more than 30 % after cryo fixation. In addition, the weak correlation between spine neck width and head volume seen after chemical fixation was not present in cryo-fixed spines. Our data suggest that spine neck geometry is independent of the spine head volume, with cryo fixation showing enhanced spine head compartmentalization and a higher predicted electrical resistance between spine head and parent dendrite.

PDFDOI

02 /Specification & Classification

Click any tag to browse matching papers
Citations
44
FWCI
2.40
Field percentile
top 11%

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.